一种基于运动和远距离图像的巩膜识别新方法

Sinan H. Alkassar, W. L. Woo, S. Dlay, J. Chambers
{"title":"一种基于运动和远距离图像的巩膜识别新方法","authors":"Sinan H. Alkassar, W. L. Woo, S. Dlay, J. Chambers","doi":"10.1109/IWBF.2016.7449677","DOIUrl":null,"url":null,"abstract":"Sclera blood vessels have been investigated recently as an efficient biometric trait. Capturing this part of the eye with a normal camera using visible-wavelength images rather than near-infrared images has provoked research interest. However, processing noisy sclera images captured at-a-distance and on-the-move has not been extensively investigated. Therefore in this paper, we propose a new method for minimizing the effect of distance on sclera recognition. This method involves sclera template rotation alignment and a distance scaling method to minimize the error rates when noisy eye images are captured at-a-distance and on-the-move. The experimental results using the on-the-move and at-a-distance UBIRIS.v2 database show a significant improvement in term of accuracy and error rates.","PeriodicalId":282164,"journal":{"name":"2016 4th International Conference on Biometrics and Forensics (IWBF)","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"A novel method for sclera recognition with images captured on-the-move and at-a-distance\",\"authors\":\"Sinan H. Alkassar, W. L. Woo, S. Dlay, J. Chambers\",\"doi\":\"10.1109/IWBF.2016.7449677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sclera blood vessels have been investigated recently as an efficient biometric trait. Capturing this part of the eye with a normal camera using visible-wavelength images rather than near-infrared images has provoked research interest. However, processing noisy sclera images captured at-a-distance and on-the-move has not been extensively investigated. Therefore in this paper, we propose a new method for minimizing the effect of distance on sclera recognition. This method involves sclera template rotation alignment and a distance scaling method to minimize the error rates when noisy eye images are captured at-a-distance and on-the-move. The experimental results using the on-the-move and at-a-distance UBIRIS.v2 database show a significant improvement in term of accuracy and error rates.\",\"PeriodicalId\":282164,\"journal\":{\"name\":\"2016 4th International Conference on Biometrics and Forensics (IWBF)\",\"volume\":\"103 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 4th International Conference on Biometrics and Forensics (IWBF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWBF.2016.7449677\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 4th International Conference on Biometrics and Forensics (IWBF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWBF.2016.7449677","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

巩膜血管作为一种有效的生物特征最近得到了研究。用普通相机捕捉眼睛的这一部分,使用可见光波长图像而不是近红外图像,引起了研究的兴趣。然而,处理在远距离和运动中捕获的有噪声的巩膜图像还没有得到广泛的研究。因此,我们提出了一种新的方法来最小化距离对巩膜识别的影响。该方法包括巩膜模板旋转对齐和距离缩放方法,以最大限度地减少在远距离和移动中捕获有噪声的眼睛图像时的错误率。使用移动和远程UBIRIS的实验结果。V2数据库在准确率和错误率方面有显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel method for sclera recognition with images captured on-the-move and at-a-distance
Sclera blood vessels have been investigated recently as an efficient biometric trait. Capturing this part of the eye with a normal camera using visible-wavelength images rather than near-infrared images has provoked research interest. However, processing noisy sclera images captured at-a-distance and on-the-move has not been extensively investigated. Therefore in this paper, we propose a new method for minimizing the effect of distance on sclera recognition. This method involves sclera template rotation alignment and a distance scaling method to minimize the error rates when noisy eye images are captured at-a-distance and on-the-move. The experimental results using the on-the-move and at-a-distance UBIRIS.v2 database show a significant improvement in term of accuracy and error rates.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Periocular biometrics: databases, algorithms and directions Empirical validation of likelihood ratio methods – A case study in forensic speaker recognition On the analysis of factors influencing the performance of facial age progression Walking direction identification using perceptual hashing Signature recognition: establishing human baseline performance via crowdsourcing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1