{"title":"MEMS温度稳定","authors":"D. B. Pazychev, R. N. Sadekov","doi":"10.23919/icins43215.2020.9133899","DOIUrl":null,"url":null,"abstract":"The article discusses a method for reducing the MEMS sensor temperature-dependent errors, using the temperature stabilization system of the sensor. The article presents the results of a full-scale experiment confirming the improved accuracy characteristics of the sensor in comparison with the traditional method of compensation for temperature errors.","PeriodicalId":127936,"journal":{"name":"2020 27th Saint Petersburg International Conference on Integrated Navigation Systems (ICINS)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"MEMS Temperature Stabilization\",\"authors\":\"D. B. Pazychev, R. N. Sadekov\",\"doi\":\"10.23919/icins43215.2020.9133899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article discusses a method for reducing the MEMS sensor temperature-dependent errors, using the temperature stabilization system of the sensor. The article presents the results of a full-scale experiment confirming the improved accuracy characteristics of the sensor in comparison with the traditional method of compensation for temperature errors.\",\"PeriodicalId\":127936,\"journal\":{\"name\":\"2020 27th Saint Petersburg International Conference on Integrated Navigation Systems (ICINS)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 27th Saint Petersburg International Conference on Integrated Navigation Systems (ICINS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/icins43215.2020.9133899\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 27th Saint Petersburg International Conference on Integrated Navigation Systems (ICINS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/icins43215.2020.9133899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The article discusses a method for reducing the MEMS sensor temperature-dependent errors, using the temperature stabilization system of the sensor. The article presents the results of a full-scale experiment confirming the improved accuracy characteristics of the sensor in comparison with the traditional method of compensation for temperature errors.