基于电容式身体通道通信的可穿戴生命信号监测样机

Qi Huang, Waseem Alkhayer, M. Fouda, Abdulkadir Celik, A. Eltawil
{"title":"基于电容式身体通道通信的可穿戴生命信号监测样机","authors":"Qi Huang, Waseem Alkhayer, M. Fouda, Abdulkadir Celik, A. Eltawil","doi":"10.1109/BSN56160.2022.9928512","DOIUrl":null,"url":null,"abstract":"Wireless body area network (WBAN) provides a means for seamless individual health monitoring without imposing restrictive limitations on normal daily routines. To date, Radio Frequency (RF) transceivers have been the technology of choice, however, drawbacks such as vulnerability to body shadowing effects, higher power consumption due to omnidirectional radiation and security concerns, have prompted the adoption of transceivers that use the human body channel for communication. In this paper, a vital signal monitoring transceiver prototype based on the human body channel communication (HBC), using commercially available chipsets is presented. RF and HBC communications are briefly reviewed and compared, and different schemes of HBC are introduced. A circuit model that represents the human body channel is then discussed and simulations are presented to illustrate the influence of the return path capacitance and receiver terminations on the path loss. The architecture of the transceiver prototype is then introduced where it is designed at a 21 MHz IEEE 802.15.6 standard-compliant carrier frequency. Finally, the performance of the transceiver, including the bit error rate (BER) and power efficiency, are characterized. Path loss is measured for two different scenarios, where variations of up to 5 dB were observed due to environmental effects. Energy efficiency measured at a maximum data-rate of 1.3 Mbps was found to be 8.3 nJ/b.","PeriodicalId":150990,"journal":{"name":"2022 IEEE-EMBS International Conference on Wearable and Implantable Body Sensor Networks (BSN)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Wearable Vital Signal Monitoring Prototype Based on Capacitive Body Channel Communication\",\"authors\":\"Qi Huang, Waseem Alkhayer, M. Fouda, Abdulkadir Celik, A. Eltawil\",\"doi\":\"10.1109/BSN56160.2022.9928512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wireless body area network (WBAN) provides a means for seamless individual health monitoring without imposing restrictive limitations on normal daily routines. To date, Radio Frequency (RF) transceivers have been the technology of choice, however, drawbacks such as vulnerability to body shadowing effects, higher power consumption due to omnidirectional radiation and security concerns, have prompted the adoption of transceivers that use the human body channel for communication. In this paper, a vital signal monitoring transceiver prototype based on the human body channel communication (HBC), using commercially available chipsets is presented. RF and HBC communications are briefly reviewed and compared, and different schemes of HBC are introduced. A circuit model that represents the human body channel is then discussed and simulations are presented to illustrate the influence of the return path capacitance and receiver terminations on the path loss. The architecture of the transceiver prototype is then introduced where it is designed at a 21 MHz IEEE 802.15.6 standard-compliant carrier frequency. Finally, the performance of the transceiver, including the bit error rate (BER) and power efficiency, are characterized. Path loss is measured for two different scenarios, where variations of up to 5 dB were observed due to environmental effects. Energy efficiency measured at a maximum data-rate of 1.3 Mbps was found to be 8.3 nJ/b.\",\"PeriodicalId\":150990,\"journal\":{\"name\":\"2022 IEEE-EMBS International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE-EMBS International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN56160.2022.9928512\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE-EMBS International Conference on Wearable and Implantable Body Sensor Networks (BSN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN56160.2022.9928512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

无线体域网络(WBAN)提供了一种不受日常生活限制的无缝个人健康监测手段。迄今为止,射频(RF)收发器一直是首选技术,然而,诸如易受人体阴影效应的影响,由于全向辐射和安全问题导致的更高功耗等缺点促使采用使用人体信道进行通信的收发器。本文介绍了一种基于人体信道通信(HBC)的生命信号监测收发器原型,该收发器采用市售芯片组。对射频通信和HBC通信进行了简要的回顾和比较,并介绍了不同的HBC通信方案。然后讨论了一个代表人体通道的电路模型,并给出了仿真来说明返回路径电容和接收器终端对路径损耗的影响。然后介绍了收发器原型的架构,其中它被设计为符合21 MHz IEEE 802.15.6标准的载波频率。最后,对收发器的误码率和功率效率等性能进行了分析。在两种不同的情况下测量了路径损耗,其中由于环境影响观察到高达5db的变化。在1.3 Mbps的最大数据速率下测量的能源效率为8.3 nJ/b。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Wearable Vital Signal Monitoring Prototype Based on Capacitive Body Channel Communication
Wireless body area network (WBAN) provides a means for seamless individual health monitoring without imposing restrictive limitations on normal daily routines. To date, Radio Frequency (RF) transceivers have been the technology of choice, however, drawbacks such as vulnerability to body shadowing effects, higher power consumption due to omnidirectional radiation and security concerns, have prompted the adoption of transceivers that use the human body channel for communication. In this paper, a vital signal monitoring transceiver prototype based on the human body channel communication (HBC), using commercially available chipsets is presented. RF and HBC communications are briefly reviewed and compared, and different schemes of HBC are introduced. A circuit model that represents the human body channel is then discussed and simulations are presented to illustrate the influence of the return path capacitance and receiver terminations on the path loss. The architecture of the transceiver prototype is then introduced where it is designed at a 21 MHz IEEE 802.15.6 standard-compliant carrier frequency. Finally, the performance of the transceiver, including the bit error rate (BER) and power efficiency, are characterized. Path loss is measured for two different scenarios, where variations of up to 5 dB were observed due to environmental effects. Energy efficiency measured at a maximum data-rate of 1.3 Mbps was found to be 8.3 nJ/b.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
SixthSense: Smart Integrated Extreme Environment Health Monitor with Sensory Feedback for Enhanced Situation Awareness Real-Time Breathing Phase Detection Using Earbuds Microphone Finite Element Modeling of a Pressure Ulcers Preventive Bed for Neonates Prototype smartwatch device for prolonged physiological monitoring in remote environments Multimodal Time-Series Activity Forecasting for Adaptive Lifestyle Intervention Design
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1