{"title":"听觉偏侧的关键带。","authors":"B Scharf, M Florentine, C H Meiselman","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new and powerful procedure for determining frequency analysis in the auditory system, as evidence by the critical band, is described. The onset time difference, delta T, needed to lateralize 30-msec tone bursts toward the leading ear was measured as a function of the frequency difference, delta F, between the brust in one ear and the burst in the other ear. When delta F was less than the critical band, threshold delta T was constant at 100 mu sec or less, depending on center frequency; beyond the critical band, delta T increased with delta F. These dichotically measured critical bandwidths increased from 110 Hz at a center frequency of 500 Hz to 1100 Hz at a center frequency of 6000 Hz. They were unaffected by varying signal level from 25 to 80 dB or signal duration from 10 to 300 msec. The sam e critical-band values have been measured with monaural stimuli in loudness summation, maskin, detection, phase perception, consonance, and so forth.</p>","PeriodicalId":76537,"journal":{"name":"Sensory processes","volume":"1 2","pages":"109-26"},"PeriodicalIF":0.0000,"publicationDate":"1976-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Critical band in auditory lateralization.\",\"authors\":\"B Scharf, M Florentine, C H Meiselman\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A new and powerful procedure for determining frequency analysis in the auditory system, as evidence by the critical band, is described. The onset time difference, delta T, needed to lateralize 30-msec tone bursts toward the leading ear was measured as a function of the frequency difference, delta F, between the brust in one ear and the burst in the other ear. When delta F was less than the critical band, threshold delta T was constant at 100 mu sec or less, depending on center frequency; beyond the critical band, delta T increased with delta F. These dichotically measured critical bandwidths increased from 110 Hz at a center frequency of 500 Hz to 1100 Hz at a center frequency of 6000 Hz. They were unaffected by varying signal level from 25 to 80 dB or signal duration from 10 to 300 msec. The sam e critical-band values have been measured with monaural stimuli in loudness summation, maskin, detection, phase perception, consonance, and so forth.</p>\",\"PeriodicalId\":76537,\"journal\":{\"name\":\"Sensory processes\",\"volume\":\"1 2\",\"pages\":\"109-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1976-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensory processes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensory processes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new and powerful procedure for determining frequency analysis in the auditory system, as evidence by the critical band, is described. The onset time difference, delta T, needed to lateralize 30-msec tone bursts toward the leading ear was measured as a function of the frequency difference, delta F, between the brust in one ear and the burst in the other ear. When delta F was less than the critical band, threshold delta T was constant at 100 mu sec or less, depending on center frequency; beyond the critical band, delta T increased with delta F. These dichotically measured critical bandwidths increased from 110 Hz at a center frequency of 500 Hz to 1100 Hz at a center frequency of 6000 Hz. They were unaffected by varying signal level from 25 to 80 dB or signal duration from 10 to 300 msec. The sam e critical-band values have been measured with monaural stimuli in loudness summation, maskin, detection, phase perception, consonance, and so forth.