碘化铅-聚乙烯醇聚合物复合材料x射线屏蔽材料的研究

Priti Rana, Sunil Chaudhary, Kulvinder Singh
{"title":"碘化铅-聚乙烯醇聚合物复合材料x射线屏蔽材料的研究","authors":"Priti Rana, Sunil Chaudhary, Kulvinder Singh","doi":"10.52783/cienceng.v11i1.383","DOIUrl":null,"url":null,"abstract":"Now-a-days, the importance of x-rays is increasing in fields like medical diagnosis, cancer treatment, nuclear fission energy, x-ray scanning machines for airport and railway station entry and in treatment of food for preservation. But the exposure to x-rays will be harmful for the users of such facilities. Doctors, operators and researchers are required to be protected from the high energy ionizing radiations like x-rays and gamma rays.So to protect them, proper shielding is necessary. Numbers of shielding materials are used at workplaces of high radiation regions at nuclear installations.  Most commonly used, shielding material is lead glasses due to its high atomic number (Z=82). This insures high absorption by the shielding material. Recently light polymer sheets of polyvinyl alcohol (PVA) are replacing heavy glass sheets. To prepare lead polymer sheets lead compounds are mixed with polymer. In the present work, we selected to mix lead iodide in polymer composite to analyze its X-ray shielding capability. Polymer composites sheets of lead iodide with PVA were prepared by solution method. These sheets of Polymer composites were subjected to soft x-rays (30 KeV- 60KeV) switching studies at room temperature. These sheets found to provide the x-ray absorption69.6% higher than conventional shielding material like lead and are light in weight too.","PeriodicalId":214525,"journal":{"name":"Proceeding International Conference on Science and Engineering","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on Lead Iodide-Polyvinyl Alcohol Polymer Composites as an X-ray Shielding Material\",\"authors\":\"Priti Rana, Sunil Chaudhary, Kulvinder Singh\",\"doi\":\"10.52783/cienceng.v11i1.383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Now-a-days, the importance of x-rays is increasing in fields like medical diagnosis, cancer treatment, nuclear fission energy, x-ray scanning machines for airport and railway station entry and in treatment of food for preservation. But the exposure to x-rays will be harmful for the users of such facilities. Doctors, operators and researchers are required to be protected from the high energy ionizing radiations like x-rays and gamma rays.So to protect them, proper shielding is necessary. Numbers of shielding materials are used at workplaces of high radiation regions at nuclear installations.  Most commonly used, shielding material is lead glasses due to its high atomic number (Z=82). This insures high absorption by the shielding material. Recently light polymer sheets of polyvinyl alcohol (PVA) are replacing heavy glass sheets. To prepare lead polymer sheets lead compounds are mixed with polymer. In the present work, we selected to mix lead iodide in polymer composite to analyze its X-ray shielding capability. Polymer composites sheets of lead iodide with PVA were prepared by solution method. These sheets of Polymer composites were subjected to soft x-rays (30 KeV- 60KeV) switching studies at room temperature. These sheets found to provide the x-ray absorption69.6% higher than conventional shielding material like lead and are light in weight too.\",\"PeriodicalId\":214525,\"journal\":{\"name\":\"Proceeding International Conference on Science and Engineering\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceeding International Conference on Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52783/cienceng.v11i1.383\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceeding International Conference on Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52783/cienceng.v11i1.383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

如今,x射线在医学诊断、癌症治疗、核裂变能、机场和火车站入口用x射线扫描机以及食品保鲜处理等领域的重要性日益增加。但是暴露在x射线下对这些设备的使用者是有害的。医生、操作人员和研究人员必须受到保护,免受x射线和伽马射线等高能电离辐射的伤害。因此,为了保护它们,适当的屏蔽是必要的。核设施高辐射区工作场所使用了多种屏蔽材料。最常用的屏蔽材料是铅玻璃,因为它的原子序数高(Z=82)。这保证了屏蔽材料的高吸收率。最近,聚乙烯醇(PVA)的轻质聚合物片材正在取代沉重的玻璃片材。为了制备铅聚合物片材,将铅化合物与聚合物混合。本文选择在聚合物复合材料中掺入碘化铅,分析其x射线屏蔽性能。采用溶液法制备了含PVA的碘化铅聚合物复合材料片。这些聚合物复合材料薄片在室温下进行软x射线(30kev - 60KeV)开关研究。这些薄片的x射线吸收率比铅等传统屏蔽材料高69.6%,而且重量也很轻。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on Lead Iodide-Polyvinyl Alcohol Polymer Composites as an X-ray Shielding Material
Now-a-days, the importance of x-rays is increasing in fields like medical diagnosis, cancer treatment, nuclear fission energy, x-ray scanning machines for airport and railway station entry and in treatment of food for preservation. But the exposure to x-rays will be harmful for the users of such facilities. Doctors, operators and researchers are required to be protected from the high energy ionizing radiations like x-rays and gamma rays.So to protect them, proper shielding is necessary. Numbers of shielding materials are used at workplaces of high radiation regions at nuclear installations.  Most commonly used, shielding material is lead glasses due to its high atomic number (Z=82). This insures high absorption by the shielding material. Recently light polymer sheets of polyvinyl alcohol (PVA) are replacing heavy glass sheets. To prepare lead polymer sheets lead compounds are mixed with polymer. In the present work, we selected to mix lead iodide in polymer composite to analyze its X-ray shielding capability. Polymer composites sheets of lead iodide with PVA were prepared by solution method. These sheets of Polymer composites were subjected to soft x-rays (30 KeV- 60KeV) switching studies at room temperature. These sheets found to provide the x-ray absorption69.6% higher than conventional shielding material like lead and are light in weight too.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Cloud-Based HR Systems on Business Performance Metrics Use of Gesture Recognition for Differently Abled Persons Study on Lead Iodide-Polyvinyl Alcohol Polymer Composites as an X-ray Shielding Material A Novel Heterogenous Dominant Sequence Clustering for Task Scheduling and Optimal Load Balancing Using JSO in Cloud Motivational Theories and Their Relevance in Military Motivation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1