{"title":"相序对成组地下电缆损耗和外磁场的影响","authors":"B. Novák, L. Koller","doi":"10.1109/PSCE.2011.5772459","DOIUrl":null,"url":null,"abstract":"To fulfill installation requirements, sometimes, two or more cables have to be connected in parallel in a three-phase power distribution system. The division of the current among the adjacent cables is governed by several factors, such as position, phase order, and the grounding method of the metal screen. Dissimilar current distributions result in dissimilar power and magnetic-field distributions. Consequently, a modified phase order can alter the total losses and the magnetic induction above the ground. This study demonstrates this effect by finite element simulations of grouped single-core underground cables buried in flat formation, and with screens bonded and grounded at both the ends.","PeriodicalId":120665,"journal":{"name":"2011 IEEE/PES Power Systems Conference and Exposition","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of phase order on losses and outer magnetic field of grouped underground cables\",\"authors\":\"B. Novák, L. Koller\",\"doi\":\"10.1109/PSCE.2011.5772459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To fulfill installation requirements, sometimes, two or more cables have to be connected in parallel in a three-phase power distribution system. The division of the current among the adjacent cables is governed by several factors, such as position, phase order, and the grounding method of the metal screen. Dissimilar current distributions result in dissimilar power and magnetic-field distributions. Consequently, a modified phase order can alter the total losses and the magnetic induction above the ground. This study demonstrates this effect by finite element simulations of grouped single-core underground cables buried in flat formation, and with screens bonded and grounded at both the ends.\",\"PeriodicalId\":120665,\"journal\":{\"name\":\"2011 IEEE/PES Power Systems Conference and Exposition\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE/PES Power Systems Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PSCE.2011.5772459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE/PES Power Systems Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PSCE.2011.5772459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of phase order on losses and outer magnetic field of grouped underground cables
To fulfill installation requirements, sometimes, two or more cables have to be connected in parallel in a three-phase power distribution system. The division of the current among the adjacent cables is governed by several factors, such as position, phase order, and the grounding method of the metal screen. Dissimilar current distributions result in dissimilar power and magnetic-field distributions. Consequently, a modified phase order can alter the total losses and the magnetic induction above the ground. This study demonstrates this effect by finite element simulations of grouped single-core underground cables buried in flat formation, and with screens bonded and grounded at both the ends.