Pablo César Rodríguez Gómez, Jessica Lozano Flamang, Javier A. Guacaneme Moreno
{"title":"风力发电机电子仿真器采用派克变换进行功率控制","authors":"Pablo César Rodríguez Gómez, Jessica Lozano Flamang, Javier A. Guacaneme Moreno","doi":"10.1109/PEPQA.2017.7981642","DOIUrl":null,"url":null,"abstract":"This paper presents an electronic type wind emulator implementation as a power source based on the Nordex N60 Wind Turbine power curve, working on a 1000 to 1 power scale. This emulator is based on a power control using Park transform and its processing algorithm is performed in the Tiva C TM4C1294 development kit, which generates the three-phase inverter switching signals using the SPWM technique. To obtain the experimental results, the emulator behavior is verified in four power curve points, showing a better performance as the generated power increases.","PeriodicalId":256426,"journal":{"name":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Wind turbine electronic emulator using park transform for power control\",\"authors\":\"Pablo César Rodríguez Gómez, Jessica Lozano Flamang, Javier A. Guacaneme Moreno\",\"doi\":\"10.1109/PEPQA.2017.7981642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an electronic type wind emulator implementation as a power source based on the Nordex N60 Wind Turbine power curve, working on a 1000 to 1 power scale. This emulator is based on a power control using Park transform and its processing algorithm is performed in the Tiva C TM4C1294 development kit, which generates the three-phase inverter switching signals using the SPWM technique. To obtain the experimental results, the emulator behavior is verified in four power curve points, showing a better performance as the generated power increases.\",\"PeriodicalId\":256426,\"journal\":{\"name\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEPQA.2017.7981642\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEPQA.2017.7981642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
本文介绍了一种基于Nordex N60风力发电机功率曲线的电子式风力模拟器作为电源的实现,工作在1000比1的功率比例下。该仿真器基于Park变换的功率控制,其处理算法在Tiva C TM4C1294开发套件中完成,利用SPWM技术产生三相逆变器开关信号。为了得到实验结果,仿真器在4个功率曲线点上进行了性能验证,随着功率的增加,仿真器的性能越来越好。
Wind turbine electronic emulator using park transform for power control
This paper presents an electronic type wind emulator implementation as a power source based on the Nordex N60 Wind Turbine power curve, working on a 1000 to 1 power scale. This emulator is based on a power control using Park transform and its processing algorithm is performed in the Tiva C TM4C1294 development kit, which generates the three-phase inverter switching signals using the SPWM technique. To obtain the experimental results, the emulator behavior is verified in four power curve points, showing a better performance as the generated power increases.