{"title":"IEC 61000-4-7测量方法适应CISPR A波段(9- 150khz)","authors":"A. Gallarreta, I. Fernández, D. Ritzmann, S. Lodetti, V. Khokhlov, P. Wright, Jan Meyer, D. D. L. Vega","doi":"10.1109/AMPS55790.2022.9978818","DOIUrl":null,"url":null,"abstract":"Devices connected to the low-voltage power grid generate disturbances that can cause malfunctions and thermal stress in the equipment connected to the mains or interference on power line communications. Currently, there is no normative method to measure the disturbances in the low voltage grid for the CISPR Band A (9-150 kHz). The Annex C of IEC 61000-4-30 Ed. 3 standard suggests three non-normative measurement methods, one of them is the method described in Annex B of IEC 61000-4-7for the 2-9 kHz range. This paper describes a proposal to adapt this method to the CISPR Band A: the RM-A method. This method aims at obtaining results of similar amplitude, with a higher granularity in the time domain, and avoiding a high computational burden due to the broader frequency range. Moreover, a more accurate detection of high-level short impulsive disturbances is obtained. The performance of the RM-A method is evaluated using a data set of recordings from the low voltage grid. The proposed method has been presented to IEC SC77A/WG9 as a first stage of a more complex method, for its potential inclusions in the IEC 61000-4-30 Ed. 4.","PeriodicalId":253296,"journal":{"name":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"208 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Adaptation of the IEC 61000-4-7 Measurement Method to CISPR Band A (9-150 kHz)\",\"authors\":\"A. Gallarreta, I. Fernández, D. Ritzmann, S. Lodetti, V. Khokhlov, P. Wright, Jan Meyer, D. D. L. Vega\",\"doi\":\"10.1109/AMPS55790.2022.9978818\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Devices connected to the low-voltage power grid generate disturbances that can cause malfunctions and thermal stress in the equipment connected to the mains or interference on power line communications. Currently, there is no normative method to measure the disturbances in the low voltage grid for the CISPR Band A (9-150 kHz). The Annex C of IEC 61000-4-30 Ed. 3 standard suggests three non-normative measurement methods, one of them is the method described in Annex B of IEC 61000-4-7for the 2-9 kHz range. This paper describes a proposal to adapt this method to the CISPR Band A: the RM-A method. This method aims at obtaining results of similar amplitude, with a higher granularity in the time domain, and avoiding a high computational burden due to the broader frequency range. Moreover, a more accurate detection of high-level short impulsive disturbances is obtained. The performance of the RM-A method is evaluated using a data set of recordings from the low voltage grid. The proposed method has been presented to IEC SC77A/WG9 as a first stage of a more complex method, for its potential inclusions in the IEC 61000-4-30 Ed. 4.\",\"PeriodicalId\":253296,\"journal\":{\"name\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"volume\":\"208 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AMPS55790.2022.9978818\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMPS55790.2022.9978818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

连接到低压电网的设备产生干扰,可能导致连接到市电的设备出现故障和热应力,或干扰电力线通信。目前,CISPR A频段(9- 150khz)的低压电网扰动测量尚无规范的方法。IEC 61000-4-30 Ed. 3标准的附件C提出了三种非规范性测量方法,其中一种方法是IEC 61000-4-7附件B中描述的2-9 kHz范围的方法。本文介绍了一种将该方法应用于CISPR波段a的建议:RM-A方法。该方法旨在获得相似幅度的结果,在时域上具有更高的粒度,并且避免了由于频率范围较宽而造成的高计算负担。此外,对高阶短脉冲扰动的检测精度更高。利用低压电网的一组记录数据对RM-A方法的性能进行了评估。提议的方法已提交给IEC SC77A/WG9,作为更复杂方法的第一阶段,因为它可能包含在IEC 61000-4-30第4版中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Adaptation of the IEC 61000-4-7 Measurement Method to CISPR Band A (9-150 kHz)
Devices connected to the low-voltage power grid generate disturbances that can cause malfunctions and thermal stress in the equipment connected to the mains or interference on power line communications. Currently, there is no normative method to measure the disturbances in the low voltage grid for the CISPR Band A (9-150 kHz). The Annex C of IEC 61000-4-30 Ed. 3 standard suggests three non-normative measurement methods, one of them is the method described in Annex B of IEC 61000-4-7for the 2-9 kHz range. This paper describes a proposal to adapt this method to the CISPR Band A: the RM-A method. This method aims at obtaining results of similar amplitude, with a higher granularity in the time domain, and avoiding a high computational burden due to the broader frequency range. Moreover, a more accurate detection of high-level short impulsive disturbances is obtained. The performance of the RM-A method is evaluated using a data set of recordings from the low voltage grid. The proposed method has been presented to IEC SC77A/WG9 as a first stage of a more complex method, for its potential inclusions in the IEC 61000-4-30 Ed. 4.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Time domain symmetry parameters analysis for series arc fault detection A Bi-objective Optimal PMU Placement Strategy Reconciling Costs and State Estimation Uncertainty Latency Characterization of a Wide Area Monitoring Protection and Control Application in the Italian Transmission System Welcome Message from the Chairmen Evaluation of composite voltage test parameters in the case of the combination power frequency and switching impulse
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1