{"title":"开关柜局部放电引起的瞬态接地电压仿真","authors":"Yinwei Li, Youyuan Wang, Guojun Lu, Jin Wang, Jun Xiong","doi":"10.1109/ICHVE.2010.5640801","DOIUrl":null,"url":null,"abstract":"Switchgears are the key equipments in the distribution network. Operating switchgear with active Partial Discharge (PD) increases the risk of failure occurring at the time of switching leading to increased risk to the operator. PD in switchgears can be considered to take two forms, surface discharge and internal discharge, if allowed to continue, eventually causes the insulation to break down catastrophically. The electromagnetic pulses produced by PD are in large part conducted away by the surrounding metalwork but a small proportion impinges onto the inner surface of the casing. These charges escape through joints in the metalwork, or a gasket on a gas insulated switch, and pass, as local raised voltages, across the surface of the switch to earth. These pulses of charge were named by Transient Earth Voltages (TEV), and the level of these TEV signals are proportional to the condition of the insulation for switchgear of the same type and model, measured at the same point. So TEV is a very powerful comparative technique for noninvasively checking the condition of switches. In this paper, the Finite-Difference Time-Domain (FDTD) method was employed to simulate the propagation law of TEV in the switchgear. The simulation results show that, the TEV amplitude is proportional to the PD pulse amplitude, increases with PD pulse width decrease and decrease with the distance between detection point and PD source.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"35","resultStr":"{\"title\":\"Simulation of transient earth voltages aroused by partial discharge in switchgears\",\"authors\":\"Yinwei Li, Youyuan Wang, Guojun Lu, Jin Wang, Jun Xiong\",\"doi\":\"10.1109/ICHVE.2010.5640801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Switchgears are the key equipments in the distribution network. Operating switchgear with active Partial Discharge (PD) increases the risk of failure occurring at the time of switching leading to increased risk to the operator. PD in switchgears can be considered to take two forms, surface discharge and internal discharge, if allowed to continue, eventually causes the insulation to break down catastrophically. The electromagnetic pulses produced by PD are in large part conducted away by the surrounding metalwork but a small proportion impinges onto the inner surface of the casing. These charges escape through joints in the metalwork, or a gasket on a gas insulated switch, and pass, as local raised voltages, across the surface of the switch to earth. These pulses of charge were named by Transient Earth Voltages (TEV), and the level of these TEV signals are proportional to the condition of the insulation for switchgear of the same type and model, measured at the same point. So TEV is a very powerful comparative technique for noninvasively checking the condition of switches. In this paper, the Finite-Difference Time-Domain (FDTD) method was employed to simulate the propagation law of TEV in the switchgear. The simulation results show that, the TEV amplitude is proportional to the PD pulse amplitude, increases with PD pulse width decrease and decrease with the distance between detection point and PD source.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

摘要

开关柜是配电网中的关键设备。带主动局部放电(PD)的开关柜操作增加了开关时发生故障的风险,从而增加了操作人员的风险。开关柜中的局部放电可以认为有表面放电和内部放电两种形式,如果任其发展下去,最终会导致绝缘发生灾难性的击穿。PD产生的电磁脉冲大部分被周围的金属制品传导出去,但有一小部分会撞击到套管的内表面。这些电荷通过金属制品的接头或气体绝缘开关上的垫片逸出,并作为局部升高的电压通过开关表面到达地球。这些电荷脉冲被称为瞬态接地电压(TEV),这些TEV信号的电平与同一类型和型号的开关设备在同一点测量的绝缘状况成正比。因此TEV是一种非常有效的无创检测开关状态的比较技术。本文采用时域有限差分(FDTD)方法模拟了TEV在开关柜中的传播规律。仿真结果表明,TEV幅值与PD脉冲幅值成正比,随PD脉冲宽度的减小而增大,随检测点与PD源距离的减小而减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation of transient earth voltages aroused by partial discharge in switchgears
Switchgears are the key equipments in the distribution network. Operating switchgear with active Partial Discharge (PD) increases the risk of failure occurring at the time of switching leading to increased risk to the operator. PD in switchgears can be considered to take two forms, surface discharge and internal discharge, if allowed to continue, eventually causes the insulation to break down catastrophically. The electromagnetic pulses produced by PD are in large part conducted away by the surrounding metalwork but a small proportion impinges onto the inner surface of the casing. These charges escape through joints in the metalwork, or a gasket on a gas insulated switch, and pass, as local raised voltages, across the surface of the switch to earth. These pulses of charge were named by Transient Earth Voltages (TEV), and the level of these TEV signals are proportional to the condition of the insulation for switchgear of the same type and model, measured at the same point. So TEV is a very powerful comparative technique for noninvasively checking the condition of switches. In this paper, the Finite-Difference Time-Domain (FDTD) method was employed to simulate the propagation law of TEV in the switchgear. The simulation results show that, the TEV amplitude is proportional to the PD pulse amplitude, increases with PD pulse width decrease and decrease with the distance between detection point and PD source.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Non-destructive test methods for hollow-core composite insulators Investigation of the effect of conductor temperature on AC power line corona Field characteristics and dielectric tests on an IGBT module plate Ultra wide band response of partial discharge test circuit The expert transformer monitoring system in substation structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1