Ruixing Liang, Max J. Kerensky, Eli Curry, Griffin Mess, Rasika Thombre, Serene Kamal, Fariba Aghabaglou, Richard Mejia, Francisco Chavez, Kyle Morrison, Nitish Thakor, N. Theodore, A. Manbachi
{"title":"设计一个精确的台式表征设备:用于定位和实施治疗超声设备和设备的声学测量平台(振幅)","authors":"Ruixing Liang, Max J. Kerensky, Eli Curry, Griffin Mess, Rasika Thombre, Serene Kamal, Fariba Aghabaglou, Richard Mejia, Francisco Chavez, Kyle Morrison, Nitish Thakor, N. Theodore, A. Manbachi","doi":"10.1115/dmd2022-1046","DOIUrl":null,"url":null,"abstract":"\n Focused ultrasound (FUS) is becoming widely researched for medical therapies due to its high penetration depth, spatial resolution, and affordability. Applications of FUS range from high intensity focused ultrasound (HIFU) for the ablation of cancerous tumors to low intensity focused ultrasound (LIFU) for the treatment of neurological conditions like essential tremors. A key step in developing these treatments and their corresponding FUS devices is characterizing the emitted ultrasound from the proposed transducer. However, a bottleneck exists at this verification and validation stage; current characterization techniques lack the robustness of reliably recording below a 5μm resolution. This level of accuracy is needed to adequately design devices which can target cells like astrocytes or other desired target tissues at this scale. Our Acoustic Measurement Platform for Localizing and Implementing Therapeutic Ultrasound Devices and Equipment (AMPLITUDE) is a solution which enables engineers, scientists, and clinicians to confidently characterize their equipment in a benchtop setting. It achieves this resolution by utilizing an all-in-one water conditioning unit, linear stepper motors with a theoretical step size of 1 μm and a 1% standard deviation on repetitive experiments, as well as signal processing techniques. This system can be used throughout the product timeline including prototyping, verifying efficacy, FDA testing, and routine check-ups during clinical use.","PeriodicalId":236105,"journal":{"name":"2022 Design of Medical Devices Conference","volume":"119 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Designing an Accurate Benchtop Characterization Device: An Acoustic Measurement Platform for Localizing and Implementing Therapeutic Ultrasound Devices and Equipment (Amplitude)\",\"authors\":\"Ruixing Liang, Max J. Kerensky, Eli Curry, Griffin Mess, Rasika Thombre, Serene Kamal, Fariba Aghabaglou, Richard Mejia, Francisco Chavez, Kyle Morrison, Nitish Thakor, N. Theodore, A. Manbachi\",\"doi\":\"10.1115/dmd2022-1046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Focused ultrasound (FUS) is becoming widely researched for medical therapies due to its high penetration depth, spatial resolution, and affordability. Applications of FUS range from high intensity focused ultrasound (HIFU) for the ablation of cancerous tumors to low intensity focused ultrasound (LIFU) for the treatment of neurological conditions like essential tremors. A key step in developing these treatments and their corresponding FUS devices is characterizing the emitted ultrasound from the proposed transducer. However, a bottleneck exists at this verification and validation stage; current characterization techniques lack the robustness of reliably recording below a 5μm resolution. This level of accuracy is needed to adequately design devices which can target cells like astrocytes or other desired target tissues at this scale. Our Acoustic Measurement Platform for Localizing and Implementing Therapeutic Ultrasound Devices and Equipment (AMPLITUDE) is a solution which enables engineers, scientists, and clinicians to confidently characterize their equipment in a benchtop setting. It achieves this resolution by utilizing an all-in-one water conditioning unit, linear stepper motors with a theoretical step size of 1 μm and a 1% standard deviation on repetitive experiments, as well as signal processing techniques. This system can be used throughout the product timeline including prototyping, verifying efficacy, FDA testing, and routine check-ups during clinical use.\",\"PeriodicalId\":236105,\"journal\":{\"name\":\"2022 Design of Medical Devices Conference\",\"volume\":\"119 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Design of Medical Devices Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/dmd2022-1046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Design of Medical Devices Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2022-1046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Designing an Accurate Benchtop Characterization Device: An Acoustic Measurement Platform for Localizing and Implementing Therapeutic Ultrasound Devices and Equipment (Amplitude)
Focused ultrasound (FUS) is becoming widely researched for medical therapies due to its high penetration depth, spatial resolution, and affordability. Applications of FUS range from high intensity focused ultrasound (HIFU) for the ablation of cancerous tumors to low intensity focused ultrasound (LIFU) for the treatment of neurological conditions like essential tremors. A key step in developing these treatments and their corresponding FUS devices is characterizing the emitted ultrasound from the proposed transducer. However, a bottleneck exists at this verification and validation stage; current characterization techniques lack the robustness of reliably recording below a 5μm resolution. This level of accuracy is needed to adequately design devices which can target cells like astrocytes or other desired target tissues at this scale. Our Acoustic Measurement Platform for Localizing and Implementing Therapeutic Ultrasound Devices and Equipment (AMPLITUDE) is a solution which enables engineers, scientists, and clinicians to confidently characterize their equipment in a benchtop setting. It achieves this resolution by utilizing an all-in-one water conditioning unit, linear stepper motors with a theoretical step size of 1 μm and a 1% standard deviation on repetitive experiments, as well as signal processing techniques. This system can be used throughout the product timeline including prototyping, verifying efficacy, FDA testing, and routine check-ups during clinical use.