{"title":"acorad公司5mm厚CdTe探测器的评估","authors":"A. Garson, I. Jung, J. Perkins, H. Krawczynski","doi":"10.1109/NSSMIC.2005.1596292","DOIUrl":null,"url":null,"abstract":"Using 2/spl times/2/spl times/0.5 cm/sup 3/ cadmium telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8/spl times/8 anode pixels. We investigate the I-V characteristics and energy resolution of the detectors for different contact materials and surface treatments. After biasing the detectors for a certain time, the dark currents increase dramatically. Our studies show that the time before breakdown decreases for higher detector temperatures and for higher applied bias voltages. We obtained the best results with a Pt cathode contact and In anode pixels when we heat the detector to 90/spl deg/C for 30 minutes prior to depositing the In contacts. Flood-illuminating the detector with 662 keV X-rays, we measured the pulse length distribution and derived an electron mobility of /spl sim/860 cm/sup 2/ V/sup -1/s/sup -1/. We show that the energy resolution can be improved by correcting the anode signals for the depth of the primary interaction. Operated at a temperature of -40/spl deg/C and a cathode bias voltage of -500 V, the best pixels of the best detector achieved full width half maximum (FWHM) energy resolutions of 8 keV (6.4%) and 23 keV (3.4%) at 122 keV and 662 keV, respectively.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Evaluation of 5 mm-thick CdTe detectors from the company Acrorad\",\"authors\":\"A. Garson, I. Jung, J. Perkins, H. Krawczynski\",\"doi\":\"10.1109/NSSMIC.2005.1596292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using 2/spl times/2/spl times/0.5 cm/sup 3/ cadmium telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8/spl times/8 anode pixels. We investigate the I-V characteristics and energy resolution of the detectors for different contact materials and surface treatments. After biasing the detectors for a certain time, the dark currents increase dramatically. Our studies show that the time before breakdown decreases for higher detector temperatures and for higher applied bias voltages. We obtained the best results with a Pt cathode contact and In anode pixels when we heat the detector to 90/spl deg/C for 30 minutes prior to depositing the In contacts. Flood-illuminating the detector with 662 keV X-rays, we measured the pulse length distribution and derived an electron mobility of /spl sim/860 cm/sup 2/ V/sup -1/s/sup -1/. We show that the energy resolution can be improved by correcting the anode signals for the depth of the primary interaction. Operated at a temperature of -40/spl deg/C and a cathode bias voltage of -500 V, the best pixels of the best detector achieved full width half maximum (FWHM) energy resolutions of 8 keV (6.4%) and 23 keV (3.4%) at 122 keV and 662 keV, respectively.\",\"PeriodicalId\":105619,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2005.1596292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of 5 mm-thick CdTe detectors from the company Acrorad
Using 2/spl times/2/spl times/0.5 cm/sup 3/ cadmium telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8/spl times/8 anode pixels. We investigate the I-V characteristics and energy resolution of the detectors for different contact materials and surface treatments. After biasing the detectors for a certain time, the dark currents increase dramatically. Our studies show that the time before breakdown decreases for higher detector temperatures and for higher applied bias voltages. We obtained the best results with a Pt cathode contact and In anode pixels when we heat the detector to 90/spl deg/C for 30 minutes prior to depositing the In contacts. Flood-illuminating the detector with 662 keV X-rays, we measured the pulse length distribution and derived an electron mobility of /spl sim/860 cm/sup 2/ V/sup -1/s/sup -1/. We show that the energy resolution can be improved by correcting the anode signals for the depth of the primary interaction. Operated at a temperature of -40/spl deg/C and a cathode bias voltage of -500 V, the best pixels of the best detector achieved full width half maximum (FWHM) energy resolutions of 8 keV (6.4%) and 23 keV (3.4%) at 122 keV and 662 keV, respectively.