采用可控双粘性梁致动器的矫形器抑制ADL上肢震颤

Rcv Loureiro, J. Belda-Lois, E. R. Lima, J. Pons, J. Sánchez-Lacuesta, W. Harwin
{"title":"采用可控双粘性梁致动器的矫形器抑制ADL上肢震颤","authors":"Rcv Loureiro, J. Belda-Lois, E. R. Lima, J. Pons, J. Sánchez-Lacuesta, W. Harwin","doi":"10.1109/ICORR.2005.1501065","DOIUrl":null,"url":null,"abstract":"Neuromuscular disorders affect millions of people worldwide. Upper limb tremor is a common symptom, and due to its complex aetiology it is difficult to compensate for except, in particular cases by surgical intervention or drug therapy. Wearable devices that mechanically compensate for limb tremor could benefit a considerable number of patients, but the technology to assist suffers in this way is under-developed. In this paper we propose an innovative orthosis that can dynamically suppress pathological tremor, by applying viscous damping to the affected limb in a controlled manner. The orthosis design utilises a new actuator design based on magneto-rheological fluids that efficiently deliver damping action in response to the instantaneous tremor frequency and amplitude.","PeriodicalId":131431,"journal":{"name":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"72","resultStr":"{\"title\":\"Upper limb tremor suppression in ADL via an orthosis incorporating a controllable double viscous beam actuator\",\"authors\":\"Rcv Loureiro, J. Belda-Lois, E. R. Lima, J. Pons, J. Sánchez-Lacuesta, W. Harwin\",\"doi\":\"10.1109/ICORR.2005.1501065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neuromuscular disorders affect millions of people worldwide. Upper limb tremor is a common symptom, and due to its complex aetiology it is difficult to compensate for except, in particular cases by surgical intervention or drug therapy. Wearable devices that mechanically compensate for limb tremor could benefit a considerable number of patients, but the technology to assist suffers in this way is under-developed. In this paper we propose an innovative orthosis that can dynamically suppress pathological tremor, by applying viscous damping to the affected limb in a controlled manner. The orthosis design utilises a new actuator design based on magneto-rheological fluids that efficiently deliver damping action in response to the instantaneous tremor frequency and amplitude.\",\"PeriodicalId\":131431,\"journal\":{\"name\":\"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"72\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICORR.2005.1501065\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2005.1501065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 72

摘要

神经肌肉疾病影响着全世界数百万人。上肢震颤是一种常见的症状,由于其复杂的病因,很难补偿,除非在特殊情况下通过手术干预或药物治疗。机械补偿肢体震颤的可穿戴设备可以使相当多的患者受益,但以这种方式帮助患者的技术还不发达。在本文中,我们提出了一种创新的矫形器,可以动态地抑制病理性震颤,通过在受影响的肢体上以可控的方式施加粘性阻尼。矫形器的设计采用了一种基于磁流变流体的新型致动器设计,可以有效地响应瞬时震颤频率和幅度,提供阻尼作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Upper limb tremor suppression in ADL via an orthosis incorporating a controllable double viscous beam actuator
Neuromuscular disorders affect millions of people worldwide. Upper limb tremor is a common symptom, and due to its complex aetiology it is difficult to compensate for except, in particular cases by surgical intervention or drug therapy. Wearable devices that mechanically compensate for limb tremor could benefit a considerable number of patients, but the technology to assist suffers in this way is under-developed. In this paper we propose an innovative orthosis that can dynamically suppress pathological tremor, by applying viscous damping to the affected limb in a controlled manner. The orthosis design utilises a new actuator design based on magneto-rheological fluids that efficiently deliver damping action in response to the instantaneous tremor frequency and amplitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A dual input device for self-assisted control of a virtual pendulum Realizing a posture-based wearable antigravity muscles support system for lower extremities Adjustable robotic tendon using a 'Jack Spring'/spl trade/ A 3-D rehabilitation system for upper limbs developed in a 5-year NEDO project and its clinical testing A motorized gravity compensation mechanism used for active rehabilitation of upper limbs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1