干扰下急性炎症反应的鲁棒约束药物剂量调节

Meriç Çetin, S. Beyhan
{"title":"干扰下急性炎症反应的鲁棒约束药物剂量调节","authors":"Meriç Çetin, S. Beyhan","doi":"10.18100/ijamec.815606","DOIUrl":null,"url":null,"abstract":"Mathematical modelling of the biological processes, diseases and organs are important for the model-based control of diseases. Due to unmodeled dynamics, unknown and external disturbances, the performance of controllers based on these models are degraded for the accurate control. Therefore, robust controllers are need especially for the applications on patients. Inflammation, the cause of many complex biological phenomena and diseases, is a nonlinear process that is difficult to control. In this paper, continuous-time sliding-mode controller has been designed for the control of acute inflammation response (AIR) and antibacterial drug infusion under external disturbances both for septic and aseptic cases. Sliding-mode controller (SMC) is mostly used to control nonlinear systems against external disturbances and parametric uncertainties. Beside the control signal generation, we propose constraints on the control signals based on the clinical experiences such that the applied control signal is suitable for the health and improves the performance of the controller. Due to the multiple equilibrium point on the behavior of the acute inflammation response, it is difficult to design such model-based controllers without input constraints. In the numerical applications, septic death case and aseptic death case with disturbances are controlled and acceptable performances are obtained for future clinical applications.","PeriodicalId":120305,"journal":{"name":"International Journal of Applied Mathematics Electronics and Computers","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Robust Constrained Drug Dosage Regulation of Acute Inflammation Response Under Disturbances\",\"authors\":\"Meriç Çetin, S. Beyhan\",\"doi\":\"10.18100/ijamec.815606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mathematical modelling of the biological processes, diseases and organs are important for the model-based control of diseases. Due to unmodeled dynamics, unknown and external disturbances, the performance of controllers based on these models are degraded for the accurate control. Therefore, robust controllers are need especially for the applications on patients. Inflammation, the cause of many complex biological phenomena and diseases, is a nonlinear process that is difficult to control. In this paper, continuous-time sliding-mode controller has been designed for the control of acute inflammation response (AIR) and antibacterial drug infusion under external disturbances both for septic and aseptic cases. Sliding-mode controller (SMC) is mostly used to control nonlinear systems against external disturbances and parametric uncertainties. Beside the control signal generation, we propose constraints on the control signals based on the clinical experiences such that the applied control signal is suitable for the health and improves the performance of the controller. Due to the multiple equilibrium point on the behavior of the acute inflammation response, it is difficult to design such model-based controllers without input constraints. In the numerical applications, septic death case and aseptic death case with disturbances are controlled and acceptable performances are obtained for future clinical applications.\",\"PeriodicalId\":120305,\"journal\":{\"name\":\"International Journal of Applied Mathematics Electronics and Computers\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Mathematics Electronics and Computers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18100/ijamec.815606\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Mathematics Electronics and Computers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18100/ijamec.815606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

生物过程、疾病和器官的数学建模对于基于模型的疾病控制非常重要。由于未建模的动力学、未知和外部干扰,基于这些模型的控制器的性能会降低,无法实现精确控制。因此,在病人身上的应用尤其需要鲁棒控制器。炎症是许多复杂生物现象和疾病的成因,是一个难以控制的非线性过程。本文设计了连续时间滑模控制器,用于控制脓毒症和无菌病例在外界干扰下的急性炎症反应(AIR)和抗菌药物输注。滑模控制器(SMC)主要用于控制非线性系统免受外部干扰和参数不确定性的影响。在控制信号生成的基础上,根据临床经验提出控制信号的约束条件,使所应用的控制信号适合于人体健康,提高了控制器的性能。由于急性炎症反应的行为存在多个平衡点,因此难以设计无输入约束的基于模型的控制器。在数值应用中,控制了脓毒性死亡和无菌性死亡的干扰情况,并获得了可接受的性能,为今后的临床应用提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robust Constrained Drug Dosage Regulation of Acute Inflammation Response Under Disturbances
Mathematical modelling of the biological processes, diseases and organs are important for the model-based control of diseases. Due to unmodeled dynamics, unknown and external disturbances, the performance of controllers based on these models are degraded for the accurate control. Therefore, robust controllers are need especially for the applications on patients. Inflammation, the cause of many complex biological phenomena and diseases, is a nonlinear process that is difficult to control. In this paper, continuous-time sliding-mode controller has been designed for the control of acute inflammation response (AIR) and antibacterial drug infusion under external disturbances both for septic and aseptic cases. Sliding-mode controller (SMC) is mostly used to control nonlinear systems against external disturbances and parametric uncertainties. Beside the control signal generation, we propose constraints on the control signals based on the clinical experiences such that the applied control signal is suitable for the health and improves the performance of the controller. Due to the multiple equilibrium point on the behavior of the acute inflammation response, it is difficult to design such model-based controllers without input constraints. In the numerical applications, septic death case and aseptic death case with disturbances are controlled and acceptable performances are obtained for future clinical applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative analysis of ANFIS models in Prediction of Streamflow: the case of Seyhan Basin Prediction of electromagnetic power density emitted from GSM base stations by using multiple linear regression Epileptic seizure detection combining power spectral density and high-frequency oscillations Adaptive Neural-Fuzzy controller design combined with LQR to control the position of gantry crane Evaluation of the performance of an unmanned aerial vehicle with artificial intelligence support and Mavlink protocol designed for response to social incidents response
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1