Anirban Das, Tsung-Cheng Chen, Yi-Ting Lin, Chao‐Sung Lai, Y. Liao, Chia‐Ming Yang
{"title":"基于模拟微镜光可寻址电位传感器的超高扫描速度化学图像传感器","authors":"Anirban Das, Tsung-Cheng Chen, Yi-Ting Lin, Chao‐Sung Lai, Y. Liao, Chia‐Ming Yang","doi":"10.1109/ICSENS.2013.6688484","DOIUrl":null,"url":null,"abstract":"In chemical image sensor, spatial resolution and scanning speed are the most important factors which may need to optimize and trade off. Before the minimization of spatial resolution, scanning speed of system needs to be improved to have an image in a short time within few seconds. In this study, ultra-high scanning speed of light addressable potentiometric sensor (LAPS) could be achieved by means of the combination of laser diode and single analog micro-mirror in light source. In the constant bias operation, an U-shape of pH solution can be detected within 8.5 sec for 14×121 points in the area of 3.2 mm×6.12 mm by using 5 kHz of ac signal in laser diode. The image resolution of the present LAPS system with 10 μm-thick Si3N4/3 nm-thick SiO2 on 500 μm-thick silicon wafer is 0.0116 mm2 which could be further improved by LAPS structure optimization with thinner substrate. A chemical image sensor with ultra-high scanning speed is demonstrated by the application of analog micro-mirror for LAPS.","PeriodicalId":258260,"journal":{"name":"2013 IEEE SENSORS","volume":"422 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Ultra-high scanning speed chemical image sensor based on light addressable potentiometric sensor with analog micro-mirror\",\"authors\":\"Anirban Das, Tsung-Cheng Chen, Yi-Ting Lin, Chao‐Sung Lai, Y. Liao, Chia‐Ming Yang\",\"doi\":\"10.1109/ICSENS.2013.6688484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In chemical image sensor, spatial resolution and scanning speed are the most important factors which may need to optimize and trade off. Before the minimization of spatial resolution, scanning speed of system needs to be improved to have an image in a short time within few seconds. In this study, ultra-high scanning speed of light addressable potentiometric sensor (LAPS) could be achieved by means of the combination of laser diode and single analog micro-mirror in light source. In the constant bias operation, an U-shape of pH solution can be detected within 8.5 sec for 14×121 points in the area of 3.2 mm×6.12 mm by using 5 kHz of ac signal in laser diode. The image resolution of the present LAPS system with 10 μm-thick Si3N4/3 nm-thick SiO2 on 500 μm-thick silicon wafer is 0.0116 mm2 which could be further improved by LAPS structure optimization with thinner substrate. A chemical image sensor with ultra-high scanning speed is demonstrated by the application of analog micro-mirror for LAPS.\",\"PeriodicalId\":258260,\"journal\":{\"name\":\"2013 IEEE SENSORS\",\"volume\":\"422 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2013.6688484\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2013.6688484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Ultra-high scanning speed chemical image sensor based on light addressable potentiometric sensor with analog micro-mirror
In chemical image sensor, spatial resolution and scanning speed are the most important factors which may need to optimize and trade off. Before the minimization of spatial resolution, scanning speed of system needs to be improved to have an image in a short time within few seconds. In this study, ultra-high scanning speed of light addressable potentiometric sensor (LAPS) could be achieved by means of the combination of laser diode and single analog micro-mirror in light source. In the constant bias operation, an U-shape of pH solution can be detected within 8.5 sec for 14×121 points in the area of 3.2 mm×6.12 mm by using 5 kHz of ac signal in laser diode. The image resolution of the present LAPS system with 10 μm-thick Si3N4/3 nm-thick SiO2 on 500 μm-thick silicon wafer is 0.0116 mm2 which could be further improved by LAPS structure optimization with thinner substrate. A chemical image sensor with ultra-high scanning speed is demonstrated by the application of analog micro-mirror for LAPS.