{"title":"模数转换和谐波由于角度定位误差在磁场测量","authors":"Kiseon Kim","doi":"10.1109/IMTC.1994.351961","DOIUrl":null,"url":null,"abstract":"Analog-to-digital conversion pertaining to the rotating coil-based magnetic field measurement systems requires an angular positioning as a sample-timing reference, which inherently introduces unwanted harmonics due to the positioning jitter. We have adopted two practical models for the positioning jitter: a random positioning and a systematic positioning errors. For each positioning error, we analyzed the magnitude of the harmonics. Further, we have introduced a positioning correction scheme to reduce the unwanted harmonics, and analyzed the reduced magnitude to show its significance or the multipole measurement system design.<<ETX>>","PeriodicalId":231484,"journal":{"name":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analog-to-digital conversion and harmonics due to the angular positioning error in magnetic field measurement\",\"authors\":\"Kiseon Kim\",\"doi\":\"10.1109/IMTC.1994.351961\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analog-to-digital conversion pertaining to the rotating coil-based magnetic field measurement systems requires an angular positioning as a sample-timing reference, which inherently introduces unwanted harmonics due to the positioning jitter. We have adopted two practical models for the positioning jitter: a random positioning and a systematic positioning errors. For each positioning error, we analyzed the magnitude of the harmonics. Further, we have introduced a positioning correction scheme to reduce the unwanted harmonics, and analyzed the reduced magnitude to show its significance or the multipole measurement system design.<<ETX>>\",\"PeriodicalId\":231484,\"journal\":{\"name\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1994.351961\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1994.351961","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analog-to-digital conversion and harmonics due to the angular positioning error in magnetic field measurement
Analog-to-digital conversion pertaining to the rotating coil-based magnetic field measurement systems requires an angular positioning as a sample-timing reference, which inherently introduces unwanted harmonics due to the positioning jitter. We have adopted two practical models for the positioning jitter: a random positioning and a systematic positioning errors. For each positioning error, we analyzed the magnitude of the harmonics. Further, we have introduced a positioning correction scheme to reduce the unwanted harmonics, and analyzed the reduced magnitude to show its significance or the multipole measurement system design.<>