基于主动轮廓双侧滤波的超声图像甲状腺结节分割

H. A. Nugroho, A. Nugroho, L. Choridah
{"title":"基于主动轮廓双侧滤波的超声图像甲状腺结节分割","authors":"H. A. Nugroho, A. Nugroho, L. Choridah","doi":"10.1109/QIR.2015.7374892","DOIUrl":null,"url":null,"abstract":"Utilization of ultrasound imaging with various resolutions as modalities for thyroid nodules examination is growing rapidly. This is consistent with an increase in incidence of thyroid malignancy. Thyroid ultrasound examination is considered superior to other medical imaging modalities for its non-invasive, practical, inexpensive and painless. In the examination process, a radiologist expects areas of thyroid nodules that can be localized precisely from the surrounding normal tissue. Thus boundary of the nodules can be seen as to be regular or irregular. Boundary is one of the important features of malignancy that doctors use to make a diagnosis. Most malignant nodules have unclear and irregular boundaries. Imprecise segmentation result will lead to misdiagnosis based on boundary characteristics. Active contour segmentation technique is applied for detecting boundary of thyroid nodules and separating them with normal tissue iteratively. However, the characteristics of the ultrasound image that brings speckle noises make the segmentation process more complicated. It also resulted in interpretation errors and inaccuracies diagnosis made by a doctor. The intricacy of irregular nodule area can not easily be solved by changing the value of iteration on active contour. Therefore, speckle noise reduction method is needed to overcome this problem so that nodule area segmented properly. In this paper speckle noise reduction is done with bilateral filter. Comparison of image segmentation results of thyroid nodules with and without bilateral filter is attached at the end of this article. The combination of bilateral filter and active contour showed better results with the edge of the nodules firmly and clear.","PeriodicalId":127270,"journal":{"name":"2015 International Conference on Quality in Research (QiR)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"28","resultStr":"{\"title\":\"Thyroid nodule segmentation using active contour bilateral filtering on ultrasound images\",\"authors\":\"H. A. Nugroho, A. Nugroho, L. Choridah\",\"doi\":\"10.1109/QIR.2015.7374892\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Utilization of ultrasound imaging with various resolutions as modalities for thyroid nodules examination is growing rapidly. This is consistent with an increase in incidence of thyroid malignancy. Thyroid ultrasound examination is considered superior to other medical imaging modalities for its non-invasive, practical, inexpensive and painless. In the examination process, a radiologist expects areas of thyroid nodules that can be localized precisely from the surrounding normal tissue. Thus boundary of the nodules can be seen as to be regular or irregular. Boundary is one of the important features of malignancy that doctors use to make a diagnosis. Most malignant nodules have unclear and irregular boundaries. Imprecise segmentation result will lead to misdiagnosis based on boundary characteristics. Active contour segmentation technique is applied for detecting boundary of thyroid nodules and separating them with normal tissue iteratively. However, the characteristics of the ultrasound image that brings speckle noises make the segmentation process more complicated. It also resulted in interpretation errors and inaccuracies diagnosis made by a doctor. The intricacy of irregular nodule area can not easily be solved by changing the value of iteration on active contour. Therefore, speckle noise reduction method is needed to overcome this problem so that nodule area segmented properly. In this paper speckle noise reduction is done with bilateral filter. Comparison of image segmentation results of thyroid nodules with and without bilateral filter is attached at the end of this article. The combination of bilateral filter and active contour showed better results with the edge of the nodules firmly and clear.\",\"PeriodicalId\":127270,\"journal\":{\"name\":\"2015 International Conference on Quality in Research (QiR)\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Quality in Research (QiR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/QIR.2015.7374892\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Quality in Research (QiR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/QIR.2015.7374892","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 28

摘要

利用不同分辨率的超声成像作为检查甲状腺结节的方式正在迅速增长。这与甲状腺恶性肿瘤发病率的增加是一致的。甲状腺超声检查以其无创、实用、廉价、无痛等优点被认为优于其他医学成像方式。在检查过程中,放射科医生希望甲状腺结节的区域能够与周围的正常组织精确定位。可见结节的边界有规则或不规则之分。肿瘤边界是医生用来诊断肿瘤的重要特征之一。大多数恶性结节边界不清、不规则。不精确的分割结果会导致基于边界特征的误诊。应用主动轮廓分割技术检测甲状腺结节的边界,并与正常组织进行迭代分离。然而,超声图像本身带来的散斑噪声的特性使得分割过程更加复杂。这也导致了医生的解释错误和不准确的诊断。通过改变活动轮廓上的迭代值,很难解决不规则结节区域的复杂性问题。因此,需要采用散斑降噪方法来克服这一问题,使结节区域得到正确分割。本文采用双边滤波器对散斑噪声进行降噪。在本文的最后附上了使用和不使用双边滤波器的甲状腺结节图像分割结果的比较。双侧滤波与主动轮廓相结合,结节边缘牢固清晰,效果较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thyroid nodule segmentation using active contour bilateral filtering on ultrasound images
Utilization of ultrasound imaging with various resolutions as modalities for thyroid nodules examination is growing rapidly. This is consistent with an increase in incidence of thyroid malignancy. Thyroid ultrasound examination is considered superior to other medical imaging modalities for its non-invasive, practical, inexpensive and painless. In the examination process, a radiologist expects areas of thyroid nodules that can be localized precisely from the surrounding normal tissue. Thus boundary of the nodules can be seen as to be regular or irregular. Boundary is one of the important features of malignancy that doctors use to make a diagnosis. Most malignant nodules have unclear and irregular boundaries. Imprecise segmentation result will lead to misdiagnosis based on boundary characteristics. Active contour segmentation technique is applied for detecting boundary of thyroid nodules and separating them with normal tissue iteratively. However, the characteristics of the ultrasound image that brings speckle noises make the segmentation process more complicated. It also resulted in interpretation errors and inaccuracies diagnosis made by a doctor. The intricacy of irregular nodule area can not easily be solved by changing the value of iteration on active contour. Therefore, speckle noise reduction method is needed to overcome this problem so that nodule area segmented properly. In this paper speckle noise reduction is done with bilateral filter. Comparison of image segmentation results of thyroid nodules with and without bilateral filter is attached at the end of this article. The combination of bilateral filter and active contour showed better results with the edge of the nodules firmly and clear.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Double-wavelength sensitive AlGaN/GaN MISIM UV sensor using multi-layer graphene as Schottky electrodes Effect of Hole Transport Layer and Electron Transport Layer on the performance of a single emissive layer Organic Light Emitting Diode The impact of different fold for cross validation of missing values imputation method on hepatitis dataset Analysis of high order dispersion and non linear effects in fiber optic transmission with Non Linear Schrodinger Equation model The effect of external magnetic field on the SPR phenomenon in modified Kretschmann configuration using magnetic cobalt ferrite nanoparticles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1