{"title":"用DGA油分析评价变压器状态","authors":"S. Ward","doi":"10.1109/CEIDP.2003.1254893","DOIUrl":null,"url":null,"abstract":"Early detection of incipient faults in transformers reduces costly unplanned outages. The most sensitive and reliable technique for evaluating the health of transformer is dissolved gas analysis (DGA). This paper uses dissolved gas analysis to study the history of different transformers in service, from which dissolved combustible gases (DCG) in oil are used as a diagnostic tool for evaluating the condition of the transformer. Oil quality and dissolved gasses tests are comparatively used for this purpose. The effect of transformer aging on dissolved combustible gasses is also examined. It is noted that the oil quality tests for transformer oil are inconclusive and that the DGA test is then necessary for complete evaluation of transformer condition.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":"{\"title\":\"Evaluating transformer condition using DGA oil analysis\",\"authors\":\"S. Ward\",\"doi\":\"10.1109/CEIDP.2003.1254893\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Early detection of incipient faults in transformers reduces costly unplanned outages. The most sensitive and reliable technique for evaluating the health of transformer is dissolved gas analysis (DGA). This paper uses dissolved gas analysis to study the history of different transformers in service, from which dissolved combustible gases (DCG) in oil are used as a diagnostic tool for evaluating the condition of the transformer. Oil quality and dissolved gasses tests are comparatively used for this purpose. The effect of transformer aging on dissolved combustible gasses is also examined. It is noted that the oil quality tests for transformer oil are inconclusive and that the DGA test is then necessary for complete evaluation of transformer condition.\",\"PeriodicalId\":306575,\"journal\":{\"name\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"54\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2003.1254893\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

摘要

及早发现变压器的早期故障,减少代价高昂的计划外停机。变压器健康评价最灵敏、最可靠的技术是溶解气体分析(DGA)。本文采用溶解气体分析的方法,研究了不同类型变压器的使用历史,并将油中溶解可燃气体(DCG)作为评价变压器状态的诊断工具。油品质量试验和溶解气体试验比较常用。还研究了变压器老化对溶解可燃气体的影响。指出变压器油的油质试验是不确定的,因此需要进行DGA试验来全面评价变压器的状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluating transformer condition using DGA oil analysis
Early detection of incipient faults in transformers reduces costly unplanned outages. The most sensitive and reliable technique for evaluating the health of transformer is dissolved gas analysis (DGA). This paper uses dissolved gas analysis to study the history of different transformers in service, from which dissolved combustible gases (DCG) in oil are used as a diagnostic tool for evaluating the condition of the transformer. Oil quality and dissolved gasses tests are comparatively used for this purpose. The effect of transformer aging on dissolved combustible gasses is also examined. It is noted that the oil quality tests for transformer oil are inconclusive and that the DGA test is then necessary for complete evaluation of transformer condition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of temperature and the mutual influence between two cavities of on the appearance of partial discharges in gaseous cavities contained in the insulator of high voltage Breakdown strength at the interface between epoxy resin and silicone rubber Surface change of polyamide nanocomposite caused by partial discharges Surface finish effects on partial discharge with embedded electrodes Roles of cumyl alcohol and crosslinked structure in homo-charge trapping in crosslinked polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1