{"title":"绝缘子表面温度对室外绝缘子闪络电压的影响","authors":"A. Rodriguez, H. Nour, F. Wang, S. Dale","doi":"10.1109/EIC.1985.7458580","DOIUrl":null,"url":null,"abstract":"Contamination on power system insulation can cause flashovers and subsequent outages when moisture deposits on the surface of the insulators to form electrolytes. Fog and light drizzle have been observed to be the most conducive form of moisture leading to flashovers; whereas, rain will wash off most of the soluble contaminants on the insulation's surface. The initial wetting is therefore a critical stage in the flashover process of contaminated insulators. This paper describes flashover tests made in a fog chamber on dc energized suspension insulators. The test insulators were preheated and the effect of the insulator's relative surface temperature on the flashover voltage was noted. The test results indicate that if the insulator's body heat can keep the surface sufficiently dry through this critical wetting stage, there can be a significant increase in the flashover voltage: as high as four times that of an insulator with a surface temperature equal to the air temperature and under the same contamination and fog conditions. This finding could be applied to abate contamination problems on insulation at severe pollution sites. To generate the required heating, an impedance element can be embedded in an insulator with a castable dielectric body. Calculations indicate that the energy necessary to obtain this internal body heating effect will be comparable to the energy losses due to leakage current and partial arcing caused by the contaminant layer.","PeriodicalId":188957,"journal":{"name":"1985 EIC 17th Electrical/Electronics Insulation Conference","volume":"898 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of insulator surface temperature on the flashover voltage of outdoor insulators\",\"authors\":\"A. Rodriguez, H. Nour, F. Wang, S. Dale\",\"doi\":\"10.1109/EIC.1985.7458580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Contamination on power system insulation can cause flashovers and subsequent outages when moisture deposits on the surface of the insulators to form electrolytes. Fog and light drizzle have been observed to be the most conducive form of moisture leading to flashovers; whereas, rain will wash off most of the soluble contaminants on the insulation's surface. The initial wetting is therefore a critical stage in the flashover process of contaminated insulators. This paper describes flashover tests made in a fog chamber on dc energized suspension insulators. The test insulators were preheated and the effect of the insulator's relative surface temperature on the flashover voltage was noted. The test results indicate that if the insulator's body heat can keep the surface sufficiently dry through this critical wetting stage, there can be a significant increase in the flashover voltage: as high as four times that of an insulator with a surface temperature equal to the air temperature and under the same contamination and fog conditions. This finding could be applied to abate contamination problems on insulation at severe pollution sites. To generate the required heating, an impedance element can be embedded in an insulator with a castable dielectric body. Calculations indicate that the energy necessary to obtain this internal body heating effect will be comparable to the energy losses due to leakage current and partial arcing caused by the contaminant layer.\",\"PeriodicalId\":188957,\"journal\":{\"name\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"volume\":\"898 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.1985.7458580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1985 EIC 17th Electrical/Electronics Insulation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.1985.7458580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当湿气沉积在绝缘子表面形成电解质时,电力系统绝缘受到污染会导致闪络和随后的停电。雾和小雨已被观察到是最有利于导致闪电的湿气形式;然而,雨水会洗掉绝缘层表面的大部分可溶性污染物。因此,初始润湿是污绝缘子闪络过程的关键阶段。本文介绍了在雾室中对直流带电悬浮绝缘子进行的闪络试验。对试验绝缘子进行预热,观察绝缘子相对表面温度对闪络电压的影响。试验结果表明,如果绝缘子的体热能够在这个关键的湿润阶段保持表面足够干燥,那么在相同的污染和雾条件下,表面温度等于空气温度的绝缘子的闪络电压可以显着增加:高达四倍。这一发现可用于减轻严重污染地点的绝缘污染问题。为了产生所需的加热,阻抗元件可以嵌入具有可浇注介电体的绝缘体中。计算表明,获得这种内部加热效应所需的能量将与由于泄漏电流和污染层引起的部分电弧造成的能量损失相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of insulator surface temperature on the flashover voltage of outdoor insulators
Contamination on power system insulation can cause flashovers and subsequent outages when moisture deposits on the surface of the insulators to form electrolytes. Fog and light drizzle have been observed to be the most conducive form of moisture leading to flashovers; whereas, rain will wash off most of the soluble contaminants on the insulation's surface. The initial wetting is therefore a critical stage in the flashover process of contaminated insulators. This paper describes flashover tests made in a fog chamber on dc energized suspension insulators. The test insulators were preheated and the effect of the insulator's relative surface temperature on the flashover voltage was noted. The test results indicate that if the insulator's body heat can keep the surface sufficiently dry through this critical wetting stage, there can be a significant increase in the flashover voltage: as high as four times that of an insulator with a surface temperature equal to the air temperature and under the same contamination and fog conditions. This finding could be applied to abate contamination problems on insulation at severe pollution sites. To generate the required heating, an impedance element can be embedded in an insulator with a castable dielectric body. Calculations indicate that the energy necessary to obtain this internal body heating effect will be comparable to the energy losses due to leakage current and partial arcing caused by the contaminant layer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A synthetic method for modelling transformer windings in the study of system switching transients Effect of environmental contamination on the formation of flashover on polymer insulating materials Evaluation of electrical insulation exposed to amorphous metal transformer core annealing temperature Plasma polymerization: A new process for electronics A new highly flexible flame retardant silicone rubber coated fiberglass sleeving
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1