中压网络中基于pmu的分布式测量系统目标不确定度的修正

Federica Costa, A. Mingotti, L. Peretto, R. Tinarelli, G. Frigo
{"title":"中压网络中基于pmu的分布式测量系统目标不确定度的修正","authors":"Federica Costa, A. Mingotti, L. Peretto, R. Tinarelli, G. Frigo","doi":"10.1109/AMPS55790.2022.9978864","DOIUrl":null,"url":null,"abstract":"The need for accurate measurements is daily increasing and recognized by system operators. Whether this aspect may be less significant for transmission networks (TNs), the same is not true for the distribution one (DN). In fact, the investments dedicated to TNs are far higher compared to those for DNs. Therefore, this work deals with the accuracy requirements needed in DNs to achieve significant measurement results. In particular, the study starts from the hypothesis that measurements are collected from typical current and voltage sensors and computed via phasor measurement units. The work first describes the typical characteristics of the DN. Second, the sources of uncertainty that contribute to the overall uncertainty of the output quantities (module and phase of currents and voltages) are detailed and analyzed. Finally, the Monte Carlo method has been applied to quantify the uncertainty of those quantities in a variety of realistic DN configurations. From the results, it emerges the significance of the measurement chain design due to its significant impact on the accuracy of the measured quantities.","PeriodicalId":253296,"journal":{"name":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Revision of target uncertainty for PMU-based distributed measurement systems in MV networks\",\"authors\":\"Federica Costa, A. Mingotti, L. Peretto, R. Tinarelli, G. Frigo\",\"doi\":\"10.1109/AMPS55790.2022.9978864\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need for accurate measurements is daily increasing and recognized by system operators. Whether this aspect may be less significant for transmission networks (TNs), the same is not true for the distribution one (DN). In fact, the investments dedicated to TNs are far higher compared to those for DNs. Therefore, this work deals with the accuracy requirements needed in DNs to achieve significant measurement results. In particular, the study starts from the hypothesis that measurements are collected from typical current and voltage sensors and computed via phasor measurement units. The work first describes the typical characteristics of the DN. Second, the sources of uncertainty that contribute to the overall uncertainty of the output quantities (module and phase of currents and voltages) are detailed and analyzed. Finally, the Monte Carlo method has been applied to quantify the uncertainty of those quantities in a variety of realistic DN configurations. From the results, it emerges the significance of the measurement chain design due to its significant impact on the accuracy of the measured quantities.\",\"PeriodicalId\":253296,\"journal\":{\"name\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AMPS55790.2022.9978864\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 12th International Workshop on Applied Measurements for Power Systems (AMPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMPS55790.2022.9978864","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对精确测量的需求日益增加,并得到系统操作员的认可。无论这一点对于传输网络(tn)是否不那么重要,对于分发网络(DN)来说却并非如此。事实上,专用于tn的投资远远高于DNs的投资。因此,本工作涉及DNs所需的精度要求,以获得显著的测量结果。特别地,本研究从一个假设开始,即从典型的电流和电压传感器收集测量数据,并通过相量测量单元计算。该工作首先描述了DN的典型特征。其次,详细分析了导致输出量总体不确定性的不确定性来源(电流和电压的模块和相位)。最后,应用蒙特卡罗方法量化了各种实际DN配置中这些量的不确定性。从结果中可以看出测量链设计的重要性,因为它对被测量的准确性有很大的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Revision of target uncertainty for PMU-based distributed measurement systems in MV networks
The need for accurate measurements is daily increasing and recognized by system operators. Whether this aspect may be less significant for transmission networks (TNs), the same is not true for the distribution one (DN). In fact, the investments dedicated to TNs are far higher compared to those for DNs. Therefore, this work deals with the accuracy requirements needed in DNs to achieve significant measurement results. In particular, the study starts from the hypothesis that measurements are collected from typical current and voltage sensors and computed via phasor measurement units. The work first describes the typical characteristics of the DN. Second, the sources of uncertainty that contribute to the overall uncertainty of the output quantities (module and phase of currents and voltages) are detailed and analyzed. Finally, the Monte Carlo method has been applied to quantify the uncertainty of those quantities in a variety of realistic DN configurations. From the results, it emerges the significance of the measurement chain design due to its significant impact on the accuracy of the measured quantities.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Time domain symmetry parameters analysis for series arc fault detection A Bi-objective Optimal PMU Placement Strategy Reconciling Costs and State Estimation Uncertainty Latency Characterization of a Wide Area Monitoring Protection and Control Application in the Italian Transmission System Welcome Message from the Chairmen Evaluation of composite voltage test parameters in the case of the combination power frequency and switching impulse
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1