{"title":"利用AMI系统检测非法用电的方法","authors":"Grzegorz Dudek, A. Gawlak, Mirosław Kornatka, J. Szkutnik","doi":"10.1109/EEM.2018.8470006","DOIUrl":null,"url":null,"abstract":"There are no proven systems on the market that deal with the detection of illegal electricity consumption. The AMI system gives new possibilities in this area. Based on the network configuration data, electric energy consumption and voltage values at the customer connection point (in phases), the analysis of electricity consumption was carried out. For the analyzed place in the network, the current was calculated from the voltage drop and the current resulting from the consumption of electricity. If the current determined from the voltage drop is greater than the current determined from the electricity consumption, it means that in relation to the recipient connected at a given point in the network, suspicion of illegal electricity consumption may be suspected.","PeriodicalId":334674,"journal":{"name":"2018 15th International Conference on the European Energy Market (EEM)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Method of Detecting Illegal Electricity Consumption Using the AMI System\",\"authors\":\"Grzegorz Dudek, A. Gawlak, Mirosław Kornatka, J. Szkutnik\",\"doi\":\"10.1109/EEM.2018.8470006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are no proven systems on the market that deal with the detection of illegal electricity consumption. The AMI system gives new possibilities in this area. Based on the network configuration data, electric energy consumption and voltage values at the customer connection point (in phases), the analysis of electricity consumption was carried out. For the analyzed place in the network, the current was calculated from the voltage drop and the current resulting from the consumption of electricity. If the current determined from the voltage drop is greater than the current determined from the electricity consumption, it means that in relation to the recipient connected at a given point in the network, suspicion of illegal electricity consumption may be suspected.\",\"PeriodicalId\":334674,\"journal\":{\"name\":\"2018 15th International Conference on the European Energy Market (EEM)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 15th International Conference on the European Energy Market (EEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEM.2018.8470006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 15th International Conference on the European Energy Market (EEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEM.2018.8470006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

市场上还没有经过验证的系统来检测非法用电。AMI系统为这一领域提供了新的可能性。根据电网配置数据、用户接入点的电能消耗和电压值(分相),进行用电量分析。对于网络中被分析的位置,通过电压降和耗电产生的电流来计算电流。如果由压降确定的电流大于由用电量确定的电流,则意味着相对于在网络中给定点连接的接收端,可能存在非法用电量的嫌疑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Method of Detecting Illegal Electricity Consumption Using the AMI System
There are no proven systems on the market that deal with the detection of illegal electricity consumption. The AMI system gives new possibilities in this area. Based on the network configuration data, electric energy consumption and voltage values at the customer connection point (in phases), the analysis of electricity consumption was carried out. For the analyzed place in the network, the current was calculated from the voltage drop and the current resulting from the consumption of electricity. If the current determined from the voltage drop is greater than the current determined from the electricity consumption, it means that in relation to the recipient connected at a given point in the network, suspicion of illegal electricity consumption may be suspected.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fast Frequency Control Services in Europe Development of the Polish Power Exchange as a Management System in Terms of Control Theory and Systems Engineering Are Consumption Tariffs Still Up-to-Date? an Operationalized Assessment of Grid Fees Enhancing N -1 Security via Building Thermostatic Load Control Strategy Improvement of DC Microgrid Voltage Regulation Based on Bidirectional Intelligent Charging Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1