{"title":"中压6脉冲CSR,具有新颖的并联有源电源滤波器连接","authors":"M. Hamad, M. Masoud, K. Ahmed, B. Williams","doi":"10.1109/IECON.2013.6699488","DOIUrl":null,"url":null,"abstract":"The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.","PeriodicalId":237327,"journal":{"name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medium voltage 6-pulse CSR with a novel shunt active power filter connection\",\"authors\":\"M. Hamad, M. Masoud, K. Ahmed, B. Williams\",\"doi\":\"10.1109/IECON.2013.6699488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.\",\"PeriodicalId\":237327,\"journal\":{\"name\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2013.6699488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2013.6699488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Medium voltage 6-pulse CSR with a novel shunt active power filter connection
The 6-pulse controlled ac/dc converter produces harmonics. The input current total harmonic distortion and the input power factor which is firing delay angle dependent are major drawbacks and a compensation technique is mandatory. This paper introduces a compensated 6-pulse current source controlled rectifier with a shunt active power filter, APF, and tapped WYE front-end transformer configuration. The shunt APF is controlled using a predictive current control. It is connected to taps on the front end transformer secondary forming a novel star auto-transformer connection where voltage matching is achieved without the need of a high frequency coupling transformer. Simulation results are presented for a medium voltage converter which is scaled to allow low-voltage experimental confirmation.