印度Nagercoil最南部半城市地区的地表臭氧变率

K. Elampari, T. Chitambarathanu, R. Krishnasharma
{"title":"印度Nagercoil最南部半城市地区的地表臭氧变率","authors":"K. Elampari, T. Chitambarathanu, R. Krishnasharma","doi":"10.1109/RSTSCC.2010.5712796","DOIUrl":null,"url":null,"abstract":"Ozone is an important atmospheric constituent due to its role both as a green house gas and an oxidant. Interactions between ozone and climate naturally occur not only in the stratosphere, but also at the earth's surface (troposphere). This study aspires to access the amount of surface ozone concentration in and around Nagercoil ( 8°11′ N, 77°29′ E ). A portable Aeroqual series 200 Ozone monitor has been used for measuring purposes. Sampling was carried out at two sites influenced by same meteorological conditions during four seasons in the period of 2007–2008. The measurements showed a well marked diurnal cycle of surface ozone concentration which clearly follows the diurnal variation of surface temperature. Results of this study have revealed that the annual mean of daily average surface ozone concentration was 19.19 ± 3.21 ppb .The highest average seasonal concentration was determined in summer and lowest in north east monsoon for both the sites. A difference of 2.73 ppb was observed in the annual mean of daily average surface ozone concentration between the two sites. Statistical t-test in this study shows that this difference is only due to the difference in the levels of VOC and precursor gas emissions.","PeriodicalId":254761,"journal":{"name":"Recent Advances in Space Technology Services and Climate Change 2010 (RSTS & CC-2010)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Surface ozone variability in the southern most semi-urban area, Nagercoil, India\",\"authors\":\"K. Elampari, T. Chitambarathanu, R. Krishnasharma\",\"doi\":\"10.1109/RSTSCC.2010.5712796\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ozone is an important atmospheric constituent due to its role both as a green house gas and an oxidant. Interactions between ozone and climate naturally occur not only in the stratosphere, but also at the earth's surface (troposphere). This study aspires to access the amount of surface ozone concentration in and around Nagercoil ( 8°11′ N, 77°29′ E ). A portable Aeroqual series 200 Ozone monitor has been used for measuring purposes. Sampling was carried out at two sites influenced by same meteorological conditions during four seasons in the period of 2007–2008. The measurements showed a well marked diurnal cycle of surface ozone concentration which clearly follows the diurnal variation of surface temperature. Results of this study have revealed that the annual mean of daily average surface ozone concentration was 19.19 ± 3.21 ppb .The highest average seasonal concentration was determined in summer and lowest in north east monsoon for both the sites. A difference of 2.73 ppb was observed in the annual mean of daily average surface ozone concentration between the two sites. Statistical t-test in this study shows that this difference is only due to the difference in the levels of VOC and precursor gas emissions.\",\"PeriodicalId\":254761,\"journal\":{\"name\":\"Recent Advances in Space Technology Services and Climate Change 2010 (RSTS & CC-2010)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Advances in Space Technology Services and Climate Change 2010 (RSTS & CC-2010)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RSTSCC.2010.5712796\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Advances in Space Technology Services and Climate Change 2010 (RSTS & CC-2010)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RSTSCC.2010.5712796","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

臭氧是一种重要的大气成分,因为它既是温室气体又是氧化剂。臭氧与气候之间的相互作用不仅自然发生在平流层,而且也发生在地球表面(对流层)。本研究旨在获得Nagercoil(8°11 ' N, 77°29 ' E)及其周围的表面臭氧浓度。便携式Aeroqual系列200臭氧监测仪已用于测量目的。2007-2008年4个季节,在气象条件相同的2个站点进行采样。测量结果表明,地表臭氧浓度的日变化周期与地表温度的日变化周期密切相关。研究结果显示,两个站点的年平均日地表臭氧浓度为19.19±3.21 ppb,夏季平均浓度最高,东北季风最低。两地地表臭氧日平均浓度年平均值相差2.73 ppb。本研究的统计t检验表明,这种差异只是由于VOC和前体气体排放水平的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Surface ozone variability in the southern most semi-urban area, Nagercoil, India
Ozone is an important atmospheric constituent due to its role both as a green house gas and an oxidant. Interactions between ozone and climate naturally occur not only in the stratosphere, but also at the earth's surface (troposphere). This study aspires to access the amount of surface ozone concentration in and around Nagercoil ( 8°11′ N, 77°29′ E ). A portable Aeroqual series 200 Ozone monitor has been used for measuring purposes. Sampling was carried out at two sites influenced by same meteorological conditions during four seasons in the period of 2007–2008. The measurements showed a well marked diurnal cycle of surface ozone concentration which clearly follows the diurnal variation of surface temperature. Results of this study have revealed that the annual mean of daily average surface ozone concentration was 19.19 ± 3.21 ppb .The highest average seasonal concentration was determined in summer and lowest in north east monsoon for both the sites. A difference of 2.73 ppb was observed in the annual mean of daily average surface ozone concentration between the two sites. Statistical t-test in this study shows that this difference is only due to the difference in the levels of VOC and precursor gas emissions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel voltage mitigation method for high power applications Environmental pollution and public health: The socio-economic analysis of the global drivers of change Micro air vehicle with nano-sensors to capture the enemy's arsenal Electronic power supply design for Sathyabama University Nano Satellite Rain fade and Ka-band Spot Beam Satellite communication in India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1