超声弹性成像中乳腺组织位移的优化

H. Mahjoubi, Romaissa Tamali, Taher Slimi
{"title":"超声弹性成像中乳腺组织位移的优化","authors":"H. Mahjoubi, Romaissa Tamali, Taher Slimi","doi":"10.31487/J.RDI.2019.03.07","DOIUrl":null,"url":null,"abstract":"The displacement of mammary tissues in static ultrasound elastography is often contaminated by the speckle noise deteriorating its quality. Several techniques have been developed in this context, in order to treat the noise present in images of breast tissue displacement, the progress of research work in noise processing is always questioned, especially that must be taken into account the trade-off between noise reduction and preservation of breast tissue texture. In this paper, a new strategy has been proposed to reduce speckle noise. The proposed method not only filters the image against noise, but also preserves the details and contours of the tissue texture. The approach developed is based on the coupling between the image reconstructions by filtered back projection (RPF) with an adaptive filter. The proposed model proposed has been validated on an in-vivo database comprising 20 images of the breast tissues displacement. Qualitative and quantitative improvements were noted. By comparing the proposed method with the wavelet technique, we show that it is more efficient in terms of calculating the standard deviation between the pixels (SD), it is better in terms of calculation of the Contrast / Noise ratio (CNR). And is much faster than the wavelet technique. The results of the proposed model are encouraging, and the chosen method is ready to be used in the improvement of images of mammary tissue displacements in ultrasound elastography.","PeriodicalId":308916,"journal":{"name":"Radiology and Medical Diagnostic Imaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Mammary Tissue Displacement in Ultrasound Elastography\",\"authors\":\"H. Mahjoubi, Romaissa Tamali, Taher Slimi\",\"doi\":\"10.31487/J.RDI.2019.03.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The displacement of mammary tissues in static ultrasound elastography is often contaminated by the speckle noise deteriorating its quality. Several techniques have been developed in this context, in order to treat the noise present in images of breast tissue displacement, the progress of research work in noise processing is always questioned, especially that must be taken into account the trade-off between noise reduction and preservation of breast tissue texture. In this paper, a new strategy has been proposed to reduce speckle noise. The proposed method not only filters the image against noise, but also preserves the details and contours of the tissue texture. The approach developed is based on the coupling between the image reconstructions by filtered back projection (RPF) with an adaptive filter. The proposed model proposed has been validated on an in-vivo database comprising 20 images of the breast tissues displacement. Qualitative and quantitative improvements were noted. By comparing the proposed method with the wavelet technique, we show that it is more efficient in terms of calculating the standard deviation between the pixels (SD), it is better in terms of calculation of the Contrast / Noise ratio (CNR). And is much faster than the wavelet technique. The results of the proposed model are encouraging, and the chosen method is ready to be used in the improvement of images of mammary tissue displacements in ultrasound elastography.\",\"PeriodicalId\":308916,\"journal\":{\"name\":\"Radiology and Medical Diagnostic Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology and Medical Diagnostic Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31487/J.RDI.2019.03.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology and Medical Diagnostic Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31487/J.RDI.2019.03.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在静态超声弹性成像中,乳腺组织的位移常受到散斑噪声的污染,从而影响成像质量。在此背景下已经发展了几种技术,为了处理乳腺组织位移图像中的噪声,噪声处理研究工作的进展一直受到质疑,特别是必须考虑到噪声降低和保留乳腺组织纹理之间的权衡。本文提出了一种降低散斑噪声的新策略。该方法不仅对图像进行了噪声滤波,而且保留了组织纹理的细节和轮廓。该方法基于滤波后投影(RPF)图像重建与自适应滤波器之间的耦合。所提出的模型已在包含20张乳腺组织位移图像的体内数据库上得到验证。注意到质量和数量上的改进。通过将该方法与小波技术进行比较,我们发现它在计算像素间标准差(SD)方面更有效,在计算对比度/噪声比(CNR)方面更好。而且比小波变换快得多。该模型的结果令人鼓舞,所选择的方法可用于超声弹性成像中乳腺组织位移图像的改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of Mammary Tissue Displacement in Ultrasound Elastography
The displacement of mammary tissues in static ultrasound elastography is often contaminated by the speckle noise deteriorating its quality. Several techniques have been developed in this context, in order to treat the noise present in images of breast tissue displacement, the progress of research work in noise processing is always questioned, especially that must be taken into account the trade-off between noise reduction and preservation of breast tissue texture. In this paper, a new strategy has been proposed to reduce speckle noise. The proposed method not only filters the image against noise, but also preserves the details and contours of the tissue texture. The approach developed is based on the coupling between the image reconstructions by filtered back projection (RPF) with an adaptive filter. The proposed model proposed has been validated on an in-vivo database comprising 20 images of the breast tissues displacement. Qualitative and quantitative improvements were noted. By comparing the proposed method with the wavelet technique, we show that it is more efficient in terms of calculating the standard deviation between the pixels (SD), it is better in terms of calculation of the Contrast / Noise ratio (CNR). And is much faster than the wavelet technique. The results of the proposed model are encouraging, and the chosen method is ready to be used in the improvement of images of mammary tissue displacements in ultrasound elastography.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Size Specific Dose Estimate in Abdominal Computed Tomography by AAPM TG Report-204 and AAPM TG Report-220 A Potential Solution to Assess the Absorbed Dose at Any Point in Breast During Digital Breast Tomosynthesis (DBT) Imaging Using a Novel Monte Carlo Simulation Software Quantitative Assessment of Iodine Intensity of Different Types of Lesions in the Low-Energy (LE) Images of Contrast-Enhanced Spectral Mammography (CESM) Radiological Correlation of Negative Appendectomies: A Clinical Audit A Short Review of Benefits of Using Chest CT Characteristics for Early diagnoses to Corona Virus Disease 2019 (COVID-19)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1