癌症热疗期间患者和医务人员的电磁场剂量

J. Bakker, R. Canters, E. Neufeld, M. Paulides, G. V. van Rhoon
{"title":"癌症热疗期间患者和医务人员的电磁场剂量","authors":"J. Bakker, R. Canters, E. Neufeld, M. Paulides, G. V. van Rhoon","doi":"10.1109/EMCEUROPE.2012.6396793","DOIUrl":null,"url":null,"abstract":"At the Erasmus Medical Center, we apply hyperthermia treatments (HT) of cancer in the pelvic area using an electromagnetic applicator installed in a Faraday shielded treatment room. Consequently, medical staff and accompanying persons are exposed to electromagnetic fields (EMF) during treatment. In the past, procedures were defined based on measurements defining compliant areas where the fields are expected to be below the exposure guidelines. Today, advanced electromagnetic models enable more precise dose assessment in the human anatomy and better evaluation of the procedures. The objective of this study was to investigate theoretically if the exposure of medical staff and accompanying persons is compliant to the guidelines when adhering to the procedures. Therefore, the whole-body averaged (SARwb) and spatial-averaged (SAR10g) specific absorption rate was assessed numerically in whole-body models of the patient, medical staff and an accompanying person. We found that predicted fields can exceed the exposure guidelines ten fold. However, the basic restrictions on SARwb and SAR10g are not exceeded for workers, but SARwb can exceed the guideline by a factor of two for accompanying persons that are in close vicinity of the applicator. In conclusion, adhering to the procedures defined in the early nineties is effective in keeping the exposure in medical staff and accompanying persons compliant to the exposure guidelines.","PeriodicalId":377100,"journal":{"name":"International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"99 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"EMF dose in patients and medical staff during hyperthermia treatment of cancer\",\"authors\":\"J. Bakker, R. Canters, E. Neufeld, M. Paulides, G. V. van Rhoon\",\"doi\":\"10.1109/EMCEUROPE.2012.6396793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"At the Erasmus Medical Center, we apply hyperthermia treatments (HT) of cancer in the pelvic area using an electromagnetic applicator installed in a Faraday shielded treatment room. Consequently, medical staff and accompanying persons are exposed to electromagnetic fields (EMF) during treatment. In the past, procedures were defined based on measurements defining compliant areas where the fields are expected to be below the exposure guidelines. Today, advanced electromagnetic models enable more precise dose assessment in the human anatomy and better evaluation of the procedures. The objective of this study was to investigate theoretically if the exposure of medical staff and accompanying persons is compliant to the guidelines when adhering to the procedures. Therefore, the whole-body averaged (SARwb) and spatial-averaged (SAR10g) specific absorption rate was assessed numerically in whole-body models of the patient, medical staff and an accompanying person. We found that predicted fields can exceed the exposure guidelines ten fold. However, the basic restrictions on SARwb and SAR10g are not exceeded for workers, but SARwb can exceed the guideline by a factor of two for accompanying persons that are in close vicinity of the applicator. In conclusion, adhering to the procedures defined in the early nineties is effective in keeping the exposure in medical staff and accompanying persons compliant to the exposure guidelines.\",\"PeriodicalId\":377100,\"journal\":{\"name\":\"International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"volume\":\"99 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEUROPE.2012.6396793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE.2012.6396793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在伊拉斯谟医疗中心,我们使用安装在法拉第屏蔽治疗室中的电磁涂抹器对骨盆区域的癌症进行热疗(HT)。因此,医务人员和随行人员在治疗期间暴露在电磁场中。在过去,程序是根据测量确定的符合区域来定义的,这些区域预计将低于暴露指南。今天,先进的电磁模型可以在人体解剖学中进行更精确的剂量评估,并更好地评估手术过程。本研究的目的是从理论上探讨医务人员及其随行人员在遵守程序时的暴露是否符合指南。因此,在患者、医务人员和陪同人员的全身模型中,对全身平均(SARwb)和空间平均(SAR10g)比吸收率进行了数值评估。我们发现,预测的辐射量可以超过暴露指南的十倍。然而,工人不会超过最低吸入量和最低吸入量10g的基本限制,但对于靠近涂抹者的随行人员,最低吸入量可超过指导值的两倍。总之,遵守90年代初确定的程序可以有效地使医务人员和随行人员的接触符合接触准则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EMF dose in patients and medical staff during hyperthermia treatment of cancer
At the Erasmus Medical Center, we apply hyperthermia treatments (HT) of cancer in the pelvic area using an electromagnetic applicator installed in a Faraday shielded treatment room. Consequently, medical staff and accompanying persons are exposed to electromagnetic fields (EMF) during treatment. In the past, procedures were defined based on measurements defining compliant areas where the fields are expected to be below the exposure guidelines. Today, advanced electromagnetic models enable more precise dose assessment in the human anatomy and better evaluation of the procedures. The objective of this study was to investigate theoretically if the exposure of medical staff and accompanying persons is compliant to the guidelines when adhering to the procedures. Therefore, the whole-body averaged (SARwb) and spatial-averaged (SAR10g) specific absorption rate was assessed numerically in whole-body models of the patient, medical staff and an accompanying person. We found that predicted fields can exceed the exposure guidelines ten fold. However, the basic restrictions on SARwb and SAR10g are not exceeded for workers, but SARwb can exceed the guideline by a factor of two for accompanying persons that are in close vicinity of the applicator. In conclusion, adhering to the procedures defined in the early nineties is effective in keeping the exposure in medical staff and accompanying persons compliant to the exposure guidelines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Antenna factor determination with Antenna Impedance measurements Determination of common mode currents with generalized mixed mode parameters An overview of the impacts of three high power electromagnetic (HPEM) threats on Smart Grids Terahertz metamaterials with dual band high refractive index Time-domain test for material electromagnetic pulse shielding effectiveness based on shielding black-box windows method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1