G. Raman, Dr. Suvanam Sasidhar Babu, P. S. Venkataramu, M. Nagaraja
{"title":"基于灵敏度因子的改进研究,包括线路中断事故下的事实装置","authors":"G. Raman, Dr. Suvanam Sasidhar Babu, P. S. Venkataramu, M. Nagaraja","doi":"10.1109/ICPEC.2013.6527625","DOIUrl":null,"url":null,"abstract":"In this paper, sensitivity analysis of transmission line is carried out by using line outage of transmission line. For each of the line outage highly sensitive line is identified and Static Var Compensator and Thyristor Controlled Series Capacitors are individually connected in this line and the system improvement as indicated by voltage profiles are illustrated. The study is carried out on IEEE 14 bus system using Mi-Power software.","PeriodicalId":176900,"journal":{"name":"2013 International Conference on Power, Energy and Control (ICPEC)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Sensitivity factor based improvement studies incorporating facts devices under line outage contingency\",\"authors\":\"G. Raman, Dr. Suvanam Sasidhar Babu, P. S. Venkataramu, M. Nagaraja\",\"doi\":\"10.1109/ICPEC.2013.6527625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, sensitivity analysis of transmission line is carried out by using line outage of transmission line. For each of the line outage highly sensitive line is identified and Static Var Compensator and Thyristor Controlled Series Capacitors are individually connected in this line and the system improvement as indicated by voltage profiles are illustrated. The study is carried out on IEEE 14 bus system using Mi-Power software.\",\"PeriodicalId\":176900,\"journal\":{\"name\":\"2013 International Conference on Power, Energy and Control (ICPEC)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Conference on Power, Energy and Control (ICPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEC.2013.6527625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Power, Energy and Control (ICPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEC.2013.6527625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sensitivity factor based improvement studies incorporating facts devices under line outage contingency
In this paper, sensitivity analysis of transmission line is carried out by using line outage of transmission line. For each of the line outage highly sensitive line is identified and Static Var Compensator and Thyristor Controlled Series Capacitors are individually connected in this line and the system improvement as indicated by voltage profiles are illustrated. The study is carried out on IEEE 14 bus system using Mi-Power software.