{"title":"PILC配电电缆状态评估的介电响应","authors":"E. Ildstad","doi":"10.1109/CEIDP.2003.1254821","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present results from a laboratory examination of the sensitivity of time-and frequency domain dielectric response measurements regarding detection of water in mass impregnated lead covered distribution (PILC) cables. The results show that increase of dc conductivity is a sensitive indication of high local content of water.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dielectric response for condition assessment of PILC distribution cables\",\"authors\":\"E. Ildstad\",\"doi\":\"10.1109/CEIDP.2003.1254821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this paper is to present results from a laboratory examination of the sensitivity of time-and frequency domain dielectric response measurements regarding detection of water in mass impregnated lead covered distribution (PILC) cables. The results show that increase of dc conductivity is a sensitive indication of high local content of water.\",\"PeriodicalId\":306575,\"journal\":{\"name\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2003.1254821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dielectric response for condition assessment of PILC distribution cables
The purpose of this paper is to present results from a laboratory examination of the sensitivity of time-and frequency domain dielectric response measurements regarding detection of water in mass impregnated lead covered distribution (PILC) cables. The results show that increase of dc conductivity is a sensitive indication of high local content of water.