{"title":"考虑频率相关接地参数的分支配电线路雷电瞬变","authors":"A. De Conti, R. Alípio","doi":"10.1109/ICLP.2016.7791375","DOIUrl":null,"url":null,"abstract":"This paper investigates the influence of considering frequency-dependent ground parameters in the calculation of lightning transients on a two-phase distribution line including the presence of branches. The analysis is focused on propagation effects along the line. It is shown that the influence of frequency-dependent ground parameters is only remarkable if a poorly-conducting ground is considered. It is also shown that the presence of line branches is likely to reduce the relative importance of considering the frequency variation of the ground parameters in the calculation of lightning transients.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lightning transients on branched distribution lines considering frequency-dependent ground parameters\",\"authors\":\"A. De Conti, R. Alípio\",\"doi\":\"10.1109/ICLP.2016.7791375\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the influence of considering frequency-dependent ground parameters in the calculation of lightning transients on a two-phase distribution line including the presence of branches. The analysis is focused on propagation effects along the line. It is shown that the influence of frequency-dependent ground parameters is only remarkable if a poorly-conducting ground is considered. It is also shown that the presence of line branches is likely to reduce the relative importance of considering the frequency variation of the ground parameters in the calculation of lightning transients.\",\"PeriodicalId\":373744,\"journal\":{\"name\":\"2016 33rd International Conference on Lightning Protection (ICLP)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 33rd International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2016.7791375\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791375","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Lightning transients on branched distribution lines considering frequency-dependent ground parameters
This paper investigates the influence of considering frequency-dependent ground parameters in the calculation of lightning transients on a two-phase distribution line including the presence of branches. The analysis is focused on propagation effects along the line. It is shown that the influence of frequency-dependent ground parameters is only remarkable if a poorly-conducting ground is considered. It is also shown that the presence of line branches is likely to reduce the relative importance of considering the frequency variation of the ground parameters in the calculation of lightning transients.