Max Koeppel, R. Engelbrecht, S. Werzinger, B. Schmauss
{"title":"基于频域非相干瑞利背散射测量的光纤传感器识别","authors":"Max Koeppel, R. Engelbrecht, S. Werzinger, B. Schmauss","doi":"10.1117/12.2263459","DOIUrl":null,"url":null,"abstract":"In this work, a fiber identification method based on incoherent optical frequency domain reflectometry (lOFDR) measurements is introduced. The proposed method uses the characteristic interference pattern of IOFDR Rayleigh backscatter measurements with a broadband light source to unambiguously recognize different initially scanned fiber segments. The recognition is achieved by crosscorrelating the spatially resolved Rayleigh backscatter profile of the fiber segment under test with a initially measured and stored backscatter profile. This profile was found to be relatively insensitive to temperature changes. It is shown that identification is possible even if the fiber segment in question is installed subsequent to 300 m of lead fiber.","PeriodicalId":198716,"journal":{"name":"2017 25th Optical Fiber Sensors Conference (OFS)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Fiber sensor identification based on incoherent Rayleigh backscatter measurements in the frequency domain\",\"authors\":\"Max Koeppel, R. Engelbrecht, S. Werzinger, B. Schmauss\",\"doi\":\"10.1117/12.2263459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, a fiber identification method based on incoherent optical frequency domain reflectometry (lOFDR) measurements is introduced. The proposed method uses the characteristic interference pattern of IOFDR Rayleigh backscatter measurements with a broadband light source to unambiguously recognize different initially scanned fiber segments. The recognition is achieved by crosscorrelating the spatially resolved Rayleigh backscatter profile of the fiber segment under test with a initially measured and stored backscatter profile. This profile was found to be relatively insensitive to temperature changes. It is shown that identification is possible even if the fiber segment in question is installed subsequent to 300 m of lead fiber.\",\"PeriodicalId\":198716,\"journal\":{\"name\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2263459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 25th Optical Fiber Sensors Conference (OFS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2263459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fiber sensor identification based on incoherent Rayleigh backscatter measurements in the frequency domain
In this work, a fiber identification method based on incoherent optical frequency domain reflectometry (lOFDR) measurements is introduced. The proposed method uses the characteristic interference pattern of IOFDR Rayleigh backscatter measurements with a broadband light source to unambiguously recognize different initially scanned fiber segments. The recognition is achieved by crosscorrelating the spatially resolved Rayleigh backscatter profile of the fiber segment under test with a initially measured and stored backscatter profile. This profile was found to be relatively insensitive to temperature changes. It is shown that identification is possible even if the fiber segment in question is installed subsequent to 300 m of lead fiber.