{"title":"用于PET层析成像前端应用的定制CMOS集成电路","authors":"D. Binkley, M. Paulus, M. Casey, R. Nutt, W. Loeffler, J. Clif, J. M. Rochelle","doi":"10.1109/NSSMIC.1993.701771","DOIUrl":null,"url":null,"abstract":"A custom CMOS integrated circuit has been designed, prototyped, and evaluated for PET tomograph front-end applications. The integrated circuit reduces the size. cost, and power consumption of existing PET frontend circuits by Over a factor of two. The integrated circuit, fabricated in a standard digital, 2 p, double-metal, double-poly, n-well CMOS process, has a die size of 6.6mmx6.4mm and power consumption of under 600 mW. The PET front-end CMOS integrated circuit processes energy, position, and timing information from a BGO block detector containing four photomultiplier tubes. Photomultiplier preamplifiers and variable gain amplifiers are co~ected to summing circuits and gated integrators to provide energy and position (x and y) signals. A constantfraction discriminator, requiring no external delay line, provides a timing output derived from the sum of the four photomultiplier signals. Eight 7- and 8-bit digital-to-analog converters. connected to a readwrite serial data interface, provide gain-control and threshold levels. The measured position, energy, and timing performance (3.05ns FWHM) of the integrated circuit is comparable to existing discrete PET frontend circuits.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"A Custom CMOS Integrated Circuit For PET Tomograph Front-end Applications\",\"authors\":\"D. Binkley, M. Paulus, M. Casey, R. Nutt, W. Loeffler, J. Clif, J. M. Rochelle\",\"doi\":\"10.1109/NSSMIC.1993.701771\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A custom CMOS integrated circuit has been designed, prototyped, and evaluated for PET tomograph front-end applications. The integrated circuit reduces the size. cost, and power consumption of existing PET frontend circuits by Over a factor of two. The integrated circuit, fabricated in a standard digital, 2 p, double-metal, double-poly, n-well CMOS process, has a die size of 6.6mmx6.4mm and power consumption of under 600 mW. The PET front-end CMOS integrated circuit processes energy, position, and timing information from a BGO block detector containing four photomultiplier tubes. Photomultiplier preamplifiers and variable gain amplifiers are co~ected to summing circuits and gated integrators to provide energy and position (x and y) signals. A constantfraction discriminator, requiring no external delay line, provides a timing output derived from the sum of the four photomultiplier signals. Eight 7- and 8-bit digital-to-analog converters. connected to a readwrite serial data interface, provide gain-control and threshold levels. The measured position, energy, and timing performance (3.05ns FWHM) of the integrated circuit is comparable to existing discrete PET frontend circuits.\",\"PeriodicalId\":287813,\"journal\":{\"name\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1993.701771\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

一个定制的CMOS集成电路已经设计,原型,并评估PET层析成像前端应用。集成电路减小了尺寸。成本和现有PET前端电路的功耗降低了两倍以上。该集成电路采用标准数字、2p、双金属、双聚、n阱CMOS工艺制造,芯片尺寸为6.6mmx6.4mm,功耗低于600 mW。PET前端CMOS集成电路处理来自包含四个光电倍增管的BGO块探测器的能量,位置和定时信息。光电倍增管前置放大器和可变增益放大器与求和电路和门控积分器共连接,提供能量和位置(x和y)信号。一个常数鉴别器,不需要外部延迟线,提供一个时序输出从四个光电倍增管信号的总和。8个7位和8位数模转换器。连接到一个读写串行数据接口,提供增益控制和阈值水平。测量到的集成电路的位置、能量和时序性能(3.05ns FWHM)与现有的离散PET前端电路相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Custom CMOS Integrated Circuit For PET Tomograph Front-end Applications
A custom CMOS integrated circuit has been designed, prototyped, and evaluated for PET tomograph front-end applications. The integrated circuit reduces the size. cost, and power consumption of existing PET frontend circuits by Over a factor of two. The integrated circuit, fabricated in a standard digital, 2 p, double-metal, double-poly, n-well CMOS process, has a die size of 6.6mmx6.4mm and power consumption of under 600 mW. The PET front-end CMOS integrated circuit processes energy, position, and timing information from a BGO block detector containing four photomultiplier tubes. Photomultiplier preamplifiers and variable gain amplifiers are co~ected to summing circuits and gated integrators to provide energy and position (x and y) signals. A constantfraction discriminator, requiring no external delay line, provides a timing output derived from the sum of the four photomultiplier signals. Eight 7- and 8-bit digital-to-analog converters. connected to a readwrite serial data interface, provide gain-control and threshold levels. The measured position, energy, and timing performance (3.05ns FWHM) of the integrated circuit is comparable to existing discrete PET frontend circuits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation Of Wavelength Shifters For Spectral Separation Of Barium Fluoride Emissions High-speed Reconstruction Of SPECT Mages With A Tailored Piecewise Neural Network A 12-channel VMEBUS-based Pulse-height Analysis Module A Bipolar Analog Front-end Integrated Circuit For The SDC Silicon Tracker Detection geometry and reconstruction error in magnetic source imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1