人工调节系统的低占空比植入间通信

C. Beck, B. Schulz, J. Nagel, H. Guth, U. Gengenbach, G. Bretthauer
{"title":"人工调节系统的低占空比植入间通信","authors":"C. Beck, B. Schulz, J. Nagel, H. Guth, U. Gengenbach, G. Bretthauer","doi":"10.1109/ISABEL.2010.5702901","DOIUrl":null,"url":null,"abstract":"The Artificial Accommodation System is an autonomous mechatronic implant aiming at restoring accommodation after cataract treatment or in the case of presbyopia. The employed sensor concept requires a continuous wireless data exchange between the two systems implanted in the left and in the right eye, respectively. In this paper, we present three strategies for establishing this inter-implant communication link and evaluate them with regard to their lowest achievable duty cycle. We also describe a two-way synchronisation method for efficient computation of the relative timer offset between both systems. The method accounts for relative clock drift, which significantly increases accuracy when using clocks with large relative drift. The proposed communication strategies are currently being implemented in the industrial, scientific and medical (ISM) band at 433 MHz using off-the-shelf transceivers and microcontrollers. First measurements of synchronisation accuracy and relative clock drift predict duty cycles in the range of 0.6%–1.0 %.","PeriodicalId":165367,"journal":{"name":"2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Low duty cycle inter-implant communication of the Artificial Accommodation System\",\"authors\":\"C. Beck, B. Schulz, J. Nagel, H. Guth, U. Gengenbach, G. Bretthauer\",\"doi\":\"10.1109/ISABEL.2010.5702901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Artificial Accommodation System is an autonomous mechatronic implant aiming at restoring accommodation after cataract treatment or in the case of presbyopia. The employed sensor concept requires a continuous wireless data exchange between the two systems implanted in the left and in the right eye, respectively. In this paper, we present three strategies for establishing this inter-implant communication link and evaluate them with regard to their lowest achievable duty cycle. We also describe a two-way synchronisation method for efficient computation of the relative timer offset between both systems. The method accounts for relative clock drift, which significantly increases accuracy when using clocks with large relative drift. The proposed communication strategies are currently being implemented in the industrial, scientific and medical (ISM) band at 433 MHz using off-the-shelf transceivers and microcontrollers. First measurements of synchronisation accuracy and relative clock drift predict duty cycles in the range of 0.6%–1.0 %.\",\"PeriodicalId\":165367,\"journal\":{\"name\":\"2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISABEL.2010.5702901\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies (ISABEL 2010)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISABEL.2010.5702901","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

人工调节系统是一种自主的机电植入物,旨在恢复白内障治疗后或老花患者的调节能力。所采用的传感器概念需要在分别植入左眼和右眼的两个系统之间进行连续的无线数据交换。在本文中,我们提出了建立这种植入间通信链路的三种策略,并对它们的最低可实现占空比进行了评估。我们还描述了一种双向同步方法,用于有效地计算两个系统之间的相对定时器偏移。该方法考虑了相对时钟漂移,当使用相对漂移较大的时钟时,可以显着提高精度。拟议的通信战略目前正在433兆赫的工业、科学和医疗(ISM)频段使用现成的收发器和微控制器实施。同步精度和相对时钟漂移的首次测量预测占空比在0.6% - 1.0%的范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Low duty cycle inter-implant communication of the Artificial Accommodation System
The Artificial Accommodation System is an autonomous mechatronic implant aiming at restoring accommodation after cataract treatment or in the case of presbyopia. The employed sensor concept requires a continuous wireless data exchange between the two systems implanted in the left and in the right eye, respectively. In this paper, we present three strategies for establishing this inter-implant communication link and evaluate them with regard to their lowest achievable duty cycle. We also describe a two-way synchronisation method for efficient computation of the relative timer offset between both systems. The method accounts for relative clock drift, which significantly increases accuracy when using clocks with large relative drift. The proposed communication strategies are currently being implemented in the industrial, scientific and medical (ISM) band at 433 MHz using off-the-shelf transceivers and microcontrollers. First measurements of synchronisation accuracy and relative clock drift predict duty cycles in the range of 0.6%–1.0 %.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Generalized quantum Turing machine and its use to find an algorithm solving NP-Complete problem Quantifying the performance of compressive sensing on scalp EEG signals Cognitive radio equipments supporting spectrum agility Bio-inspired cognitive phones based on human nervous system Power efficient wireless connectivity of a wearable data glove
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1