{"title":"ranang bangunwater Seal Drainage (WSD)","authors":"Diah Rahayu Ningtias, Bayu Wahyudi, Iqbal Firdaus","doi":"10.23960/JTAF.V8I2.2563","DOIUrl":null,"url":null,"abstract":"A Water Seal Drainage (WSD) design was made to remove air and fluid from the pleural cavity in the thorax (lung cavity) using a connecting tube or chest tube to maintain the negative pressure of the cavity. Under normal circumstances, the pleural cavity has negative pressure and only a little pleural fluid is filled. Suction pumps have a high pressure with a pressure range of -10 kPa to -80 kPa. The pressure is large enough so that it is not suitable for thorax because it can cause damage to internal organs due to high pressure. WSD specifically for thorax has a low pressure which is below -5 kPa / -40 mmHg. This WSD is equipped with a hand switch, water level and automatic Arduino Uno based exhaust system which has a pressure below -26.6 kPa / -20 cmHg to suction and pressure below -3.4 kPa / -2.6 cmHg to remove liquid from the bottle . The hand switch itself functions as a manual control to make it easier for the user, while the level sensor functions as a safety level for fluid levels in the tool and also an automatic fluid disposal system so that it is more efficient.","PeriodicalId":314761,"journal":{"name":"Jurnal Teori dan Aplikasi Fisika","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rancang Bangun Water Seal Drainage (WSD) Khusus Thorax\",\"authors\":\"Diah Rahayu Ningtias, Bayu Wahyudi, Iqbal Firdaus\",\"doi\":\"10.23960/JTAF.V8I2.2563\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A Water Seal Drainage (WSD) design was made to remove air and fluid from the pleural cavity in the thorax (lung cavity) using a connecting tube or chest tube to maintain the negative pressure of the cavity. Under normal circumstances, the pleural cavity has negative pressure and only a little pleural fluid is filled. Suction pumps have a high pressure with a pressure range of -10 kPa to -80 kPa. The pressure is large enough so that it is not suitable for thorax because it can cause damage to internal organs due to high pressure. WSD specifically for thorax has a low pressure which is below -5 kPa / -40 mmHg. This WSD is equipped with a hand switch, water level and automatic Arduino Uno based exhaust system which has a pressure below -26.6 kPa / -20 cmHg to suction and pressure below -3.4 kPa / -2.6 cmHg to remove liquid from the bottle . The hand switch itself functions as a manual control to make it easier for the user, while the level sensor functions as a safety level for fluid levels in the tool and also an automatic fluid disposal system so that it is more efficient.\",\"PeriodicalId\":314761,\"journal\":{\"name\":\"Jurnal Teori dan Aplikasi Fisika\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teori dan Aplikasi Fisika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23960/JTAF.V8I2.2563\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teori dan Aplikasi Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23960/JTAF.V8I2.2563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Rancang Bangun Water Seal Drainage (WSD) Khusus Thorax
A Water Seal Drainage (WSD) design was made to remove air and fluid from the pleural cavity in the thorax (lung cavity) using a connecting tube or chest tube to maintain the negative pressure of the cavity. Under normal circumstances, the pleural cavity has negative pressure and only a little pleural fluid is filled. Suction pumps have a high pressure with a pressure range of -10 kPa to -80 kPa. The pressure is large enough so that it is not suitable for thorax because it can cause damage to internal organs due to high pressure. WSD specifically for thorax has a low pressure which is below -5 kPa / -40 mmHg. This WSD is equipped with a hand switch, water level and automatic Arduino Uno based exhaust system which has a pressure below -26.6 kPa / -20 cmHg to suction and pressure below -3.4 kPa / -2.6 cmHg to remove liquid from the bottle . The hand switch itself functions as a manual control to make it easier for the user, while the level sensor functions as a safety level for fluid levels in the tool and also an automatic fluid disposal system so that it is more efficient.