{"title":"使用封闭系统传输设备访问一次性小瓶时的无菌性","authors":"JA Schoenenberger Arnaiz, M. Nevot-Blanc, A. Moroba-Estor, M. Gonzalez-Garcia, M. Martínez-Sogués, M. Gilabert-Sotoca","doi":"10.1136/ejhpharm-2020-eahpconf.84","DOIUrl":null,"url":null,"abstract":"Background and importance It is common practice for compounding facilities in Europe to retain partially used vials of physically stable drugs for future compounding needs; there are discrepancies in accepted beyond use dates (BUD). Canada NAPRA Model Standards specify a BUD of 6 hours based on the risk of microbial contamination for single use vials. Aim and objectives To confirm that using a closed system transfer device (CSTD, ChemoLock), in a class II B2 BSC installed in a class B compliant environment, would prevent microbial contamination of simulated single use vials and maintain their sterility even after repeated access for up to 9 days. Material and methods Under standard compounding procedures, 20 vials of growth media were accessed using ChemoLock vial adaptors. Aliquots (1 mL) were withdrawn and discarded from each vial at 0, 48, 96, 144, 168 and 216 hours. At the end of this 9 day period, samples were incubated in a microbiological laboratory. In order to test for growth of gram positive bacteria, gram negative bacteria, anaerobic microorganisms, yeast and mould, two types of growth media were used: 10 samples with tryptic soy broth (TSB) and 10 samples with fluid thioglycollate medium (FTM). Two temperature ranges (20–25°C and 30–35°C) were used for incubation to ensure optimum growth conditions for different microorganisms. Negative and positive controls for each growth media were also used. Concurrent with testing, each positive control FTM vial was inoculated with one of the following American Type Culture Collection Stock (ATCC) strains: Clostridium sporogenes, Pseudomonas aeruginosa and Staphylococcus aureus, and incubated with the test samples. TSB vials were inoculated with one of the following ATCC stock strains: Bacillus subtilis, Aspergillus brasiliensis and Candida albicans. Results No growth was observed in the negative controls or study samples after 7 days at 20–25°C or after 7 days at 30–35°C. All positive controls showed growth. Conclusion and relevance The study results suggest that single use vial sterility is maintained for up to 9 days when accessed by a ChemoLock CSTD. Prolonged sterility may support BUD extension up 9 days. BUD extension may result in improved medication supply in times of shortage, increased efficiency and could prevent waste of high cost medicines. References and/or acknowledgements ICU Medical has sponsored this study Conflict of interest Corporate sponsored research or other substantive relationships: This research was sponsored by ICU Medical Inc, San Clemente, California, USA","PeriodicalId":335223,"journal":{"name":"Section 3: Production and Compounding","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"3PC-037 Sterility of single use vials when accessed using a closed system transfer device\",\"authors\":\"JA Schoenenberger Arnaiz, M. Nevot-Blanc, A. Moroba-Estor, M. Gonzalez-Garcia, M. Martínez-Sogués, M. Gilabert-Sotoca\",\"doi\":\"10.1136/ejhpharm-2020-eahpconf.84\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and importance It is common practice for compounding facilities in Europe to retain partially used vials of physically stable drugs for future compounding needs; there are discrepancies in accepted beyond use dates (BUD). Canada NAPRA Model Standards specify a BUD of 6 hours based on the risk of microbial contamination for single use vials. Aim and objectives To confirm that using a closed system transfer device (CSTD, ChemoLock), in a class II B2 BSC installed in a class B compliant environment, would prevent microbial contamination of simulated single use vials and maintain their sterility even after repeated access for up to 9 days. Material and methods Under standard compounding procedures, 20 vials of growth media were accessed using ChemoLock vial adaptors. Aliquots (1 mL) were withdrawn and discarded from each vial at 0, 48, 96, 144, 168 and 216 hours. At the end of this 9 day period, samples were incubated in a microbiological laboratory. In order to test for growth of gram positive bacteria, gram negative bacteria, anaerobic microorganisms, yeast and mould, two types of growth media were used: 10 samples with tryptic soy broth (TSB) and 10 samples with fluid thioglycollate medium (FTM). Two temperature ranges (20–25°C and 30–35°C) were used for incubation to ensure optimum growth conditions for different microorganisms. Negative and positive controls for each growth media were also used. Concurrent with testing, each positive control FTM vial was inoculated with one of the following American Type Culture Collection Stock (ATCC) strains: Clostridium sporogenes, Pseudomonas aeruginosa and Staphylococcus aureus, and incubated with the test samples. TSB vials were inoculated with one of the following ATCC stock strains: Bacillus subtilis, Aspergillus brasiliensis and Candida albicans. Results No growth was observed in the negative controls or study samples after 7 days at 20–25°C or after 7 days at 30–35°C. All positive controls showed growth. Conclusion and relevance The study results suggest that single use vial sterility is maintained for up to 9 days when accessed by a ChemoLock CSTD. Prolonged sterility may support BUD extension up 9 days. BUD extension may result in improved medication supply in times of shortage, increased efficiency and could prevent waste of high cost medicines. References and/or acknowledgements ICU Medical has sponsored this study Conflict of interest Corporate sponsored research or other substantive relationships: This research was sponsored by ICU Medical Inc, San Clemente, California, USA\",\"PeriodicalId\":335223,\"journal\":{\"name\":\"Section 3: Production and Compounding\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Section 3: Production and Compounding\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/ejhpharm-2020-eahpconf.84\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Section 3: Production and Compounding","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/ejhpharm-2020-eahpconf.84","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景和重要性在欧洲的配药设施中,保留部分使用的物理稳定药物以备将来配药需要是一种常见的做法;接受超期使用日期(BUD)存在差异。加拿大NAPRA模型标准根据一次性小瓶的微生物污染风险规定了6小时的BUD。确认在B级合规环境中安装的II级B2 BSC中使用封闭系统转移装置(CSTD, ChemoLock),可以防止模拟一次性小瓶的微生物污染,并在重复使用长达9天后保持其无菌性。材料和方法在标准配样程序下,使用ChemoLock小瓶适配器获取20瓶培养基。在0、48、96、144、168和216小时从每个小瓶中取出等量(1ml)并丢弃。在这9天结束时,样品在微生物实验室中孵育。为了检测革兰氏阳性菌、革兰氏阴性菌、厌氧微生物、酵母菌和霉菌的生长情况,采用两种培养基:色氨酸豆汤(TSB)和液体巯基酸盐培养基(FTM)各10份。采用20-25°C和30-35°C两个温度范围进行培养,以确保不同微生物的最佳生长条件。每种培养基也采用阴性和阳性对照。在检测的同时,每个阳性对照FTM小瓶接种以下美国型培养收集库(ATCC)菌株之一:产孢梭菌、铜绿假单胞菌和金黄色葡萄球菌,并与检测样品一起孵育。TSB小瓶接种以下ATCC储备菌株之一:枯草芽孢杆菌、巴西曲霉和白色念珠菌。结果阴性对照和研究样本在20-25℃和30-35℃条件下7 d均未见生长。所有阳性对照均显示生长。结论和相关性研究结果表明,当使用ChemoLock CSTD时,一次性小瓶无菌性可维持长达9天。延长不育期可支持BUD延长9天。在药品短缺的情况下,BUD的推广可以改善药品供应,提高效率,防止高成本药品的浪费。参考文献和/或致谢ICU Medical赞助了本研究利益冲突企业赞助的研究或其他实质性关系:本研究由ICU Medical Inc, San Clemente, California, USA赞助
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3PC-037 Sterility of single use vials when accessed using a closed system transfer device
Background and importance It is common practice for compounding facilities in Europe to retain partially used vials of physically stable drugs for future compounding needs; there are discrepancies in accepted beyond use dates (BUD). Canada NAPRA Model Standards specify a BUD of 6 hours based on the risk of microbial contamination for single use vials. Aim and objectives To confirm that using a closed system transfer device (CSTD, ChemoLock), in a class II B2 BSC installed in a class B compliant environment, would prevent microbial contamination of simulated single use vials and maintain their sterility even after repeated access for up to 9 days. Material and methods Under standard compounding procedures, 20 vials of growth media were accessed using ChemoLock vial adaptors. Aliquots (1 mL) were withdrawn and discarded from each vial at 0, 48, 96, 144, 168 and 216 hours. At the end of this 9 day period, samples were incubated in a microbiological laboratory. In order to test for growth of gram positive bacteria, gram negative bacteria, anaerobic microorganisms, yeast and mould, two types of growth media were used: 10 samples with tryptic soy broth (TSB) and 10 samples with fluid thioglycollate medium (FTM). Two temperature ranges (20–25°C and 30–35°C) were used for incubation to ensure optimum growth conditions for different microorganisms. Negative and positive controls for each growth media were also used. Concurrent with testing, each positive control FTM vial was inoculated with one of the following American Type Culture Collection Stock (ATCC) strains: Clostridium sporogenes, Pseudomonas aeruginosa and Staphylococcus aureus, and incubated with the test samples. TSB vials were inoculated with one of the following ATCC stock strains: Bacillus subtilis, Aspergillus brasiliensis and Candida albicans. Results No growth was observed in the negative controls or study samples after 7 days at 20–25°C or after 7 days at 30–35°C. All positive controls showed growth. Conclusion and relevance The study results suggest that single use vial sterility is maintained for up to 9 days when accessed by a ChemoLock CSTD. Prolonged sterility may support BUD extension up 9 days. BUD extension may result in improved medication supply in times of shortage, increased efficiency and could prevent waste of high cost medicines. References and/or acknowledgements ICU Medical has sponsored this study Conflict of interest Corporate sponsored research or other substantive relationships: This research was sponsored by ICU Medical Inc, San Clemente, California, USA
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3PC-010 Development of a stable parenteral solution of topiramate for emergency treatment of status epilepticus 3PC-035 Patch tests with hazardous drugs: is it possible to ensure safety during production? 3PC-026 Cost savings associated with romiplostim repackaging in a patient with idiopathic thrombocytopenic purpura 3PC-011 Mucosectomy: feasibility study of the automated preparation of a sterile solution of 5/10% fructose glycerol 3PC-045 Retrospective study over 6 years of the trend in fungal contamination of controlled atmosphere areas within a cell therapy unit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1