Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko
{"title":"RotoWrist:使用腕带进行连续红外手腕角度跟踪","authors":"Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko","doi":"10.1145/3489849.3489886","DOIUrl":null,"url":null,"abstract":"We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.","PeriodicalId":345527,"journal":{"name":"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"RotoWrist: Continuous Infrared Wrist Angle Tracking using a Wristband\",\"authors\":\"Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko\",\"doi\":\"10.1145/3489849.3489886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.\",\"PeriodicalId\":345527,\"journal\":{\"name\":\"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology\",\"volume\":\"83 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3489849.3489886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3489849.3489886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
RotoWrist: Continuous Infrared Wrist Angle Tracking using a Wristband
We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.