RotoWrist:使用腕带进行连续红外手腕角度跟踪

Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko
{"title":"RotoWrist:使用腕带进行连续红外手腕角度跟踪","authors":"Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko","doi":"10.1145/3489849.3489886","DOIUrl":null,"url":null,"abstract":"We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.","PeriodicalId":345527,"journal":{"name":"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"RotoWrist: Continuous Infrared Wrist Angle Tracking using a Wristband\",\"authors\":\"Farshid Salemi Parizi, W. Kienzle, Eric Whitmire, Aakar Gupta, Hrvoje Benko\",\"doi\":\"10.1145/3489849.3489886\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.\",\"PeriodicalId\":345527,\"journal\":{\"name\":\"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology\",\"volume\":\"83 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3489849.3489886\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3489849.3489886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

我们介绍了RotoWrist,这是一种基于红外(IR)光的解决方案,可以使用腕带连续可靠地跟踪手腕相对于前臂的2个自由度(DoF)相对角度。跟踪系统由八个飞行时间(ToF)红外光模块组成,分布在腕带周围。我们开发了一种计算简单的跟踪方法来重建手腕的方向,而无需任何运行时训练,确保用户独立性。一项评估研究表明,RotoWrist在弯曲/伸展时实现了5.9°的跨用户中位跟踪误差,在径向和尺侧偏差时实现了6.8°的中位跟踪误差,无需校准。我们进一步展示了RotoWrist在指向任务中的性能,并将其与地面真实跟踪进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
RotoWrist: Continuous Infrared Wrist Angle Tracking using a Wristband
We introduce RotoWrist, an infrared (IR) light based solution for continuously and reliably tracking 2-degree-of-freedom (DoF) relative angle of the wrist with respect to the forearm using a wristband. The tracking system consists of eight time-of-flight (ToF) IR light modules distributed around a wristband. We developed a computationally simple tracking approach to reconstruct the orientation of the wrist without any runtime training, ensuring user independence. An evaluation study demonstrated that RotoWrist achieves a cross-user median tracking error of 5.9° in flexion/extension and 6.8° in radial and ulnar deviation with no calibration required as measured with optical ground truth. We further demonstrate the performance of RotoWrist for a pointing task and compare it against ground truth tracking.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Managing a Crisis in Virtual Reality - Tackling a Wildfire A Perceptual Evaluation of the Ground Inclination with a Simple VR Walking Platform GazeMOOC: A Gaze Data Driven Visual Analytics System for MOOC with XR Content Fluid3DGuides: A Technique for Structured 3D Drawing in VR Analysis of Detection Thresholds for Hand Redirection during Mid-Air Interactions in Virtual Reality
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1