运行中的电动机和发电机的局部放电脉冲相位图

J. Kapler, G. Stone, H. Sedding
{"title":"运行中的电动机和发电机的局部放电脉冲相位图","authors":"J. Kapler, G. Stone, H. Sedding","doi":"10.1109/ISEIM.1995.496546","DOIUrl":null,"url":null,"abstract":"Many hundreds of partial discharge test results on about 100 operating motors and generators have been reviewed. In the majority of results, the position of the partial discharges with respect to the 600 Hz phase angle was as expected from conventional partial discharge theory, as well as laboratory experiments. However, perhaps 25490 of the PPA plots were \"abnormal\" in some way. Yet these patterns are real, and are not due to noise, nor are they artifacts of the measurement system. Researchers developing pattern recognition techniques for PD pulses should be aware that patterns from operating high voltage equipment may be much more complex than the patterns obtained in laboratory apparatus.","PeriodicalId":130178,"journal":{"name":"Proceedings of 1995 International Symposium on Electrical Insulating Materials","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Partial discharge pulse phase patterns on operating motors and generators\",\"authors\":\"J. Kapler, G. Stone, H. Sedding\",\"doi\":\"10.1109/ISEIM.1995.496546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many hundreds of partial discharge test results on about 100 operating motors and generators have been reviewed. In the majority of results, the position of the partial discharges with respect to the 600 Hz phase angle was as expected from conventional partial discharge theory, as well as laboratory experiments. However, perhaps 25490 of the PPA plots were \\\"abnormal\\\" in some way. Yet these patterns are real, and are not due to noise, nor are they artifacts of the measurement system. Researchers developing pattern recognition techniques for PD pulses should be aware that patterns from operating high voltage equipment may be much more complex than the patterns obtained in laboratory apparatus.\",\"PeriodicalId\":130178,\"journal\":{\"name\":\"Proceedings of 1995 International Symposium on Electrical Insulating Materials\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 International Symposium on Electrical Insulating Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEIM.1995.496546\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 International Symposium on Electrical Insulating Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEIM.1995.496546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对大约100台运行中的电动机和发电机进行了数百次局部放电试验。在大多数结果中,相对于600 Hz相位角的部分放电位置与传统的部分放电理论以及实验室实验所期望的一致。然而,可能有25490个PPA地块在某种程度上是“异常”的。然而,这些模式是真实的,不是由于噪声,也不是测量系统的工件。开发PD脉冲模式识别技术的研究人员应该意识到,操作高压设备的模式可能比在实验室仪器中获得的模式复杂得多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Partial discharge pulse phase patterns on operating motors and generators
Many hundreds of partial discharge test results on about 100 operating motors and generators have been reviewed. In the majority of results, the position of the partial discharges with respect to the 600 Hz phase angle was as expected from conventional partial discharge theory, as well as laboratory experiments. However, perhaps 25490 of the PPA plots were "abnormal" in some way. Yet these patterns are real, and are not due to noise, nor are they artifacts of the measurement system. Researchers developing pattern recognition techniques for PD pulses should be aware that patterns from operating high voltage equipment may be much more complex than the patterns obtained in laboratory apparatus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impulse and DC breakdown tracks of air in point-plane gaps Study on conducting property of the organic PTCR material Some aspects of water tree growth in XLPE insulation exposed to DC voltage Development of polyethylene insulation diagnosis of high voltage cables in France Space charge evolution in XLPE cable insulation under high electric fields
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1