{"title":"使用新UL 943C的工业场所人员接地故障保护","authors":"Nehad El-Sherif, R. Mendler, John Trotte, Ajay Pathak","doi":"10.1109/PCICON.2014.6961906","DOIUrl":null,"url":null,"abstract":"Most refineries, drilling platforms, and chemical plants are equipped with receptacles used for powering equipment. This can present a shock hazard; therefore, NFPA and OSHA require ground-fault circuit interrupter (GFCI) on all receptacles powering equipment used by personnel and are not part of the building permanent wiring. Due to the lack of GFCI at voltages above 240 V, both NFPA and OSHA require employers to implement the assured equipment grounding conductor program for all temporary wiring installations.","PeriodicalId":264800,"journal":{"name":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Ground fault protection of personnel in industrial locations using the new UL 943C\",\"authors\":\"Nehad El-Sherif, R. Mendler, John Trotte, Ajay Pathak\",\"doi\":\"10.1109/PCICON.2014.6961906\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Most refineries, drilling platforms, and chemical plants are equipped with receptacles used for powering equipment. This can present a shock hazard; therefore, NFPA and OSHA require ground-fault circuit interrupter (GFCI) on all receptacles powering equipment used by personnel and are not part of the building permanent wiring. Due to the lack of GFCI at voltages above 240 V, both NFPA and OSHA require employers to implement the assured equipment grounding conductor program for all temporary wiring installations.\",\"PeriodicalId\":264800,\"journal\":{\"name\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCICON.2014.6961906\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICON.2014.6961906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Ground fault protection of personnel in industrial locations using the new UL 943C
Most refineries, drilling platforms, and chemical plants are equipped with receptacles used for powering equipment. This can present a shock hazard; therefore, NFPA and OSHA require ground-fault circuit interrupter (GFCI) on all receptacles powering equipment used by personnel and are not part of the building permanent wiring. Due to the lack of GFCI at voltages above 240 V, both NFPA and OSHA require employers to implement the assured equipment grounding conductor program for all temporary wiring installations.