多码CDMA移动医疗系统下行功率控制方案的设计

Chin-Feng Lin, Wen-Thong Chang, Hsin-Wang Lee, Shih-Ii Hung
{"title":"多码CDMA移动医疗系统下行功率控制方案的设计","authors":"Chin-Feng Lin, Wen-Thong Chang, Hsin-Wang Lee, Shih-Ii Hung","doi":"10.1109/ISWPC.2006.1613576","DOIUrl":null,"url":null,"abstract":"In this paper, we proposed a downlink power control scheme to apply in the multi-code CDMA mobile medicine system. The mobile medicine system contains: (i) blood pressure and body temperature measurement value, (ii) medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal and MPEG-4 CCD sensor video signal. By the help of the multi-code CDMA spread spectrum communication system with downlink power control strategy to make it possible for transmission media in this system to meet the quality of service of mobile medicine system, and achieve the purpose of the maximum resource utilization. In different media, the power is controlled according to the demand for bit error rate. Higher transmission power is given to the media requesting lower bit error rate. Numerical analysis shows that the ratio of transmission power of voice, video and data virtual channels are approximately 1:2:13 when the bit error rates for the voice, video and data are set at 10/sup -3/, 10/sup -4/ and 10/sup -7/. It is similar to the ratio of SNIR of voice, video and data transmission requirement. Meanwhile, we also test related mobile medical signal transmission and simulation.","PeriodicalId":145728,"journal":{"name":"2006 1st International Symposium on Wireless Pervasive Computing","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2006-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design of a downlink power control scheme in multi-code CDMA mobile medicine system\",\"authors\":\"Chin-Feng Lin, Wen-Thong Chang, Hsin-Wang Lee, Shih-Ii Hung\",\"doi\":\"10.1109/ISWPC.2006.1613576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we proposed a downlink power control scheme to apply in the multi-code CDMA mobile medicine system. The mobile medicine system contains: (i) blood pressure and body temperature measurement value, (ii) medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal and MPEG-4 CCD sensor video signal. By the help of the multi-code CDMA spread spectrum communication system with downlink power control strategy to make it possible for transmission media in this system to meet the quality of service of mobile medicine system, and achieve the purpose of the maximum resource utilization. In different media, the power is controlled according to the demand for bit error rate. Higher transmission power is given to the media requesting lower bit error rate. Numerical analysis shows that the ratio of transmission power of voice, video and data virtual channels are approximately 1:2:13 when the bit error rates for the voice, video and data are set at 10/sup -3/, 10/sup -4/ and 10/sup -7/. It is similar to the ratio of SNIR of voice, video and data transmission requirement. Meanwhile, we also test related mobile medical signal transmission and simulation.\",\"PeriodicalId\":145728,\"journal\":{\"name\":\"2006 1st International Symposium on Wireless Pervasive Computing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 1st International Symposium on Wireless Pervasive Computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISWPC.2006.1613576\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 1st International Symposium on Wireless Pervasive Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISWPC.2006.1613576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了一种适用于多码CDMA移动医疗系统的下行功率控制方案。移动医疗系统包含:(i)血压和体温测量值,(ii)心电图设备测量的医疗信号,(iii)移动患者病史,(iv) G.729音频信号和MPEG-4 CCD传感器视频信号。借助多码CDMA扩频通信系统的下行功率控制策略,使该系统中的传输介质能够满足移动医疗系统的服务质量,达到最大限度地利用资源的目的。在不同的介质中,功率是根据误码率的要求来控制的。要求较低误码率的介质具有较高的传输功率。数值分析表明,当语音、视频和数据的误码率分别为10/sup -3/、10/sup -4/和10/sup -7/时,语音、视频和数据虚拟信道的传输功率比约为1:2:13。它类似于语音、视频和数据传输的信噪比要求。同时,对相关的移动医疗信号传输和仿真进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a downlink power control scheme in multi-code CDMA mobile medicine system
In this paper, we proposed a downlink power control scheme to apply in the multi-code CDMA mobile medicine system. The mobile medicine system contains: (i) blood pressure and body temperature measurement value, (ii) medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal and MPEG-4 CCD sensor video signal. By the help of the multi-code CDMA spread spectrum communication system with downlink power control strategy to make it possible for transmission media in this system to meet the quality of service of mobile medicine system, and achieve the purpose of the maximum resource utilization. In different media, the power is controlled according to the demand for bit error rate. Higher transmission power is given to the media requesting lower bit error rate. Numerical analysis shows that the ratio of transmission power of voice, video and data virtual channels are approximately 1:2:13 when the bit error rates for the voice, video and data are set at 10/sup -3/, 10/sup -4/ and 10/sup -7/. It is similar to the ratio of SNIR of voice, video and data transmission requirement. Meanwhile, we also test related mobile medical signal transmission and simulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of digital filtering technique in reducing the effects of clipping of an enhanced orthogonal frequency division multiplexing system Secure data aggregation using commitment schemes and quasi commutative functions Periodic Spectrum Transmission for Single-Carrier Frequency-Domain Equalization Employing Space-Time Transmit Diversity Transmit diversity systems with antenna replacement and its application to space time block coding transmission Comparison of opportunistic scheduling policies in time-slotted AMC wireless networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1