标准风扇测试设备的特性,以适应噪音测量时的声音反射

C. D. du Plessis, S. J. van der Spuy, H. Reuter
{"title":"标准风扇测试设备的特性,以适应噪音测量时的声音反射","authors":"C. D. du Plessis, S. J. van der Spuy, H. Reuter","doi":"10.17159/2309-8988/2022/v38a3","DOIUrl":null,"url":null,"abstract":"Axial flow fans are fundamental to air-cooled condensers. While they provide the air flow for heat transfer, they also generate noise, which is a growing environmental concern. Sound reflections are characterised in an existing fan performance test facility, which does not conform to fan noise measurement standards. Corrections to the measured SPL spectrum is deduced along with the uncertainty in noise measurements. Corrections are compared to a reflection correction standard relating to buildings. This methodology can be repeated for other fan test facilities which do not comply with noise measurement standards.","PeriodicalId":331389,"journal":{"name":"R&D Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterisation of a Standard Fan Test Facility to Accommodate Reflection of Sound During Noise Measurements\",\"authors\":\"C. D. du Plessis, S. J. van der Spuy, H. Reuter\",\"doi\":\"10.17159/2309-8988/2022/v38a3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Axial flow fans are fundamental to air-cooled condensers. While they provide the air flow for heat transfer, they also generate noise, which is a growing environmental concern. Sound reflections are characterised in an existing fan performance test facility, which does not conform to fan noise measurement standards. Corrections to the measured SPL spectrum is deduced along with the uncertainty in noise measurements. Corrections are compared to a reflection correction standard relating to buildings. This methodology can be repeated for other fan test facilities which do not comply with noise measurement standards.\",\"PeriodicalId\":331389,\"journal\":{\"name\":\"R&D Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"R&D Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17159/2309-8988/2022/v38a3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"R&D Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17159/2309-8988/2022/v38a3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

轴流风机是气冷式冷凝器的基础。虽然它们为热传递提供气流,但它们也会产生噪音,这是一个日益严重的环境问题。在现有的风扇性能测试设施中,声音反射的特征不符合风扇噪声测量标准。根据噪声测量中的不确定度,推导了对测量声压级谱的修正。校正量与与建筑物有关的反射校正标准进行比较。此方法可重复用于不符合噪音测量标准的其他风扇测试设施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterisation of a Standard Fan Test Facility to Accommodate Reflection of Sound During Noise Measurements
Axial flow fans are fundamental to air-cooled condensers. While they provide the air flow for heat transfer, they also generate noise, which is a growing environmental concern. Sound reflections are characterised in an existing fan performance test facility, which does not conform to fan noise measurement standards. Corrections to the measured SPL spectrum is deduced along with the uncertainty in noise measurements. Corrections are compared to a reflection correction standard relating to buildings. This methodology can be repeated for other fan test facilities which do not comply with noise measurement standards.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of a Test Setup for Measuring all Load Components Acting on Tillage and Planting Implements Pressure Recovery Discharge Configurations for an Induced Draught Axial Flow Fan Dielectric Elastomer Actuators and Optical Character Recognition in a Braille Display Characterisation of a Standard Fan Test Facility to Accommodate Reflection of Sound During Noise Measurements An Android Application-based Surface Oust Classifier
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1