{"title":"阵列相机辐射定标的简化方法","authors":"A. Cano-García, J. Lázaro, P. Fernández","doi":"10.1109/WISP.2007.4447619","DOIUrl":null,"url":null,"abstract":"Radiometric calibration of a CCD camera is a first step when quantitative measurements for pixels values will be performed in order to extract scene characteristics. Usually, the radiometric behaviour of the camera can be modelled with a polynomial function obtained from a multi- image calibration method, which analyses several pictures taken with different exposition times. In this work, a simplification of a multi-images calibration method is proposed. The method is based on the comparison of grey values of two images only, showing that obtained results are comparables to the polynomic multi-image method. The proposed method was tested with the same images used for multi-image calibration method. Exposition times were estimated without an iterative scheme. Also a method and results for distance estimation, using inverse radiometric response function, are showed in this paper.","PeriodicalId":164902,"journal":{"name":"2007 IEEE International Symposium on Intelligent Signal Processing","volume":"402 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Simplified Method for Radiometric Calibration of an Array Camera\",\"authors\":\"A. Cano-García, J. Lázaro, P. Fernández\",\"doi\":\"10.1109/WISP.2007.4447619\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Radiometric calibration of a CCD camera is a first step when quantitative measurements for pixels values will be performed in order to extract scene characteristics. Usually, the radiometric behaviour of the camera can be modelled with a polynomial function obtained from a multi- image calibration method, which analyses several pictures taken with different exposition times. In this work, a simplification of a multi-images calibration method is proposed. The method is based on the comparison of grey values of two images only, showing that obtained results are comparables to the polynomic multi-image method. The proposed method was tested with the same images used for multi-image calibration method. Exposition times were estimated without an iterative scheme. Also a method and results for distance estimation, using inverse radiometric response function, are showed in this paper.\",\"PeriodicalId\":164902,\"journal\":{\"name\":\"2007 IEEE International Symposium on Intelligent Signal Processing\",\"volume\":\"402 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Symposium on Intelligent Signal Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WISP.2007.4447619\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Intelligent Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WISP.2007.4447619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simplified Method for Radiometric Calibration of an Array Camera
Radiometric calibration of a CCD camera is a first step when quantitative measurements for pixels values will be performed in order to extract scene characteristics. Usually, the radiometric behaviour of the camera can be modelled with a polynomial function obtained from a multi- image calibration method, which analyses several pictures taken with different exposition times. In this work, a simplification of a multi-images calibration method is proposed. The method is based on the comparison of grey values of two images only, showing that obtained results are comparables to the polynomic multi-image method. The proposed method was tested with the same images used for multi-image calibration method. Exposition times were estimated without an iterative scheme. Also a method and results for distance estimation, using inverse radiometric response function, are showed in this paper.