Terumo BABY-RX™氧合器的扩展支持

Joseph Deptula, Sherrie K Fogg, K. Glogowski, K. Fenton, Duncan F. Kim
{"title":"Terumo BABY-RX™氧合器的扩展支持","authors":"Joseph Deptula, Sherrie K Fogg, K. Glogowski, K. Fenton, Duncan F. Kim","doi":"10.1051/ject/2004364364","DOIUrl":null,"url":null,"abstract":"The Terumo Baby-RX™, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX™ also is treated with X Coating™, Terumo’s biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The oxygenator has a blood flow range of 0.1 to 1500 mL/min and operates with a minimum reservoir volume of 15 mL. A 3.2-kg patient, status post-Stage 1 Norwood, Palliation was placed on cardiopulmonary support after thrombus formation within the modified Blalock-Taussig shunt during a general surgery procedure. The extended support circuit incorporated the Baby-RX™ oxygenator for 17.5 hours. The oxygenator performed well over this time period at flows of 600–800 mL/min, sweep rates of 100–300 mL/min, FiO2 of 30–40%, and ACTs of 140–200 seconds. There were no indices of oxygenator failure noted within the time frame of support. After placement of a new systemic to pulmonary shunt, the patient was removed from support and the oxygenator drained of residual blood. No evidence of fiber damage or clot formation was noted. The patient had a successful support run without complications related to cardiopulmonary support.","PeriodicalId":309024,"journal":{"name":"The Journal of ExtraCorporeal Technology","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Extended Support With the Terumo BABY-RX™ Oxygenator\",\"authors\":\"Joseph Deptula, Sherrie K Fogg, K. Glogowski, K. Fenton, Duncan F. Kim\",\"doi\":\"10.1051/ject/2004364364\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Terumo Baby-RX™, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX™ also is treated with X Coating™, Terumo’s biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The oxygenator has a blood flow range of 0.1 to 1500 mL/min and operates with a minimum reservoir volume of 15 mL. A 3.2-kg patient, status post-Stage 1 Norwood, Palliation was placed on cardiopulmonary support after thrombus formation within the modified Blalock-Taussig shunt during a general surgery procedure. The extended support circuit incorporated the Baby-RX™ oxygenator for 17.5 hours. The oxygenator performed well over this time period at flows of 600–800 mL/min, sweep rates of 100–300 mL/min, FiO2 of 30–40%, and ACTs of 140–200 seconds. There were no indices of oxygenator failure noted within the time frame of support. After placement of a new systemic to pulmonary shunt, the patient was removed from support and the oxygenator drained of residual blood. No evidence of fiber damage or clot formation was noted. The patient had a successful support run without complications related to cardiopulmonary support.\",\"PeriodicalId\":309024,\"journal\":{\"name\":\"The Journal of ExtraCorporeal Technology\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of ExtraCorporeal Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1051/ject/2004364364\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of ExtraCorporeal Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2004364364","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

Terumo Baby-RX™是新一代低prime氧合器,最近已进入北美灌注市场。这个氧合器是专门为新生儿和婴儿设计的,并且具有任何临床可用的氧合器中最小的启动体积。BABY-RX™还采用X Coating™处理,X Coating™是Terumo的生物相容性亲水性聚合物表面涂层,可减少血小板粘附和蛋白质变性。氧合器的血流量范围为0.1至1500ml /min,最小储存器容量为15ml。在普通外科手术过程中,在改良的Blalock-Taussig分流器内形成血栓后,对3.2 kg的患者进行了缓解治疗。扩展支持电路包含Baby-RX™氧合器,可使用17.5小时。在这段时间内,氧合器在流量为600-800 mL/min,扫描速率为100-300 mL/min, FiO2为30-40%,act为140-200秒时表现良好。在支持时间框架内没有氧合器失效的指标。放置新的全身到肺分流器后,将患者从支架上取下,氧合器排出残留血液。没有发现纤维损伤或血栓形成的证据。患者有一个成功的支持运行,没有并发症相关的心肺支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Extended Support With the Terumo BABY-RX™ Oxygenator
The Terumo Baby-RX™, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX™ also is treated with X Coating™, Terumo’s biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The oxygenator has a blood flow range of 0.1 to 1500 mL/min and operates with a minimum reservoir volume of 15 mL. A 3.2-kg patient, status post-Stage 1 Norwood, Palliation was placed on cardiopulmonary support after thrombus formation within the modified Blalock-Taussig shunt during a general surgery procedure. The extended support circuit incorporated the Baby-RX™ oxygenator for 17.5 hours. The oxygenator performed well over this time period at flows of 600–800 mL/min, sweep rates of 100–300 mL/min, FiO2 of 30–40%, and ACTs of 140–200 seconds. There were no indices of oxygenator failure noted within the time frame of support. After placement of a new systemic to pulmonary shunt, the patient was removed from support and the oxygenator drained of residual blood. No evidence of fiber damage or clot formation was noted. The patient had a successful support run without complications related to cardiopulmonary support.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Standardized Therapies after ECMO Program (STEP); A Novel Approach to Pediatric post-ECMO Care Traditional vs. modified Ringer lactate-based del Nido cardioplegia impacts on clinical outcomes in patients undergoing coronary artery bypass grafting: results from a clinical trial Comparison of routine del Nido cardioplegia vs two types of modified del Nido cardioplegias for myocardial protection among patients undergoing coronary artery bypass grafting (CABG) surgeries: a randomized double-blind clinical trial. Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1