{"title":"用于三电平中性点箝位逆变器的主动热保护的PWM","authors":"T. Phan, G. Riedel, N. Oikonomou, M. Pacas","doi":"10.1109/ECCE-ASIA.2013.6579213","DOIUrl":null,"url":null,"abstract":"In high power applications, in which the discrete power switches are mounted on separate heatsinks, an overload of a semiconductor device leads to a local excessive thermal stress and eventually to a failure of the system. Despite of a control strategy that ensures the even distribution of losses in the normal operation, a local thermal overload can arise due to failures in the electronics, in the cooling system, due to an inappropriate positioning of the semiconductor device, etc. In this paper, a new fault tolerant control approach is introduced to deal with this matter. When detecting increased thermal stress of one IGBT module, the switching strategy is altered in order to reduce the load of that particular IGBT module and to redistribute the losses and consequently the heat from the affected group or valve to the other switches. Hence, the temperature of the stressed switch is kept under the critical limit and the thermal overload is reduced. In such way the reliability and the lifetime of the converter is maximized even in case of thermal failure. In the proposed novel modulation concept, the balancing of the neutral point potential of the 3L-NPC Inverter is also ensured without any additional hardware.","PeriodicalId":301487,"journal":{"name":"2013 IEEE ECCE Asia Downunder","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"PWM for active thermal protection in three level neutral point clamped inverters\",\"authors\":\"T. Phan, G. Riedel, N. Oikonomou, M. Pacas\",\"doi\":\"10.1109/ECCE-ASIA.2013.6579213\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In high power applications, in which the discrete power switches are mounted on separate heatsinks, an overload of a semiconductor device leads to a local excessive thermal stress and eventually to a failure of the system. Despite of a control strategy that ensures the even distribution of losses in the normal operation, a local thermal overload can arise due to failures in the electronics, in the cooling system, due to an inappropriate positioning of the semiconductor device, etc. In this paper, a new fault tolerant control approach is introduced to deal with this matter. When detecting increased thermal stress of one IGBT module, the switching strategy is altered in order to reduce the load of that particular IGBT module and to redistribute the losses and consequently the heat from the affected group or valve to the other switches. Hence, the temperature of the stressed switch is kept under the critical limit and the thermal overload is reduced. In such way the reliability and the lifetime of the converter is maximized even in case of thermal failure. In the proposed novel modulation concept, the balancing of the neutral point potential of the 3L-NPC Inverter is also ensured without any additional hardware.\",\"PeriodicalId\":301487,\"journal\":{\"name\":\"2013 IEEE ECCE Asia Downunder\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE ECCE Asia Downunder\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE-ASIA.2013.6579213\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE ECCE Asia Downunder","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-ASIA.2013.6579213","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

在高功率应用中,分立的电源开关安装在单独的散热器上,半导体器件的过载会导致局部过热应力,最终导致系统故障。尽管有一种控制策略可以确保在正常运行中损耗的均匀分布,但由于电子器件、冷却系统、半导体器件的不适当定位等故障,可能会出现局部热过载。本文提出了一种新的容错控制方法来解决这一问题。当检测到一个IGBT模块的热应力增加时,开关策略被改变,以减少该特定IGBT模块的负载,并重新分配损失,从而将热量从受影响的组或阀转移到其他开关。从而使应力开关温度保持在临界温度范围内,减少了热过载。这样,即使在热失效的情况下,转换器的可靠性和寿命也得到了最大化。在提出的新调制概念中,还保证了3L-NPC逆变器中性点电位的平衡,而无需任何额外的硬件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PWM for active thermal protection in three level neutral point clamped inverters
In high power applications, in which the discrete power switches are mounted on separate heatsinks, an overload of a semiconductor device leads to a local excessive thermal stress and eventually to a failure of the system. Despite of a control strategy that ensures the even distribution of losses in the normal operation, a local thermal overload can arise due to failures in the electronics, in the cooling system, due to an inappropriate positioning of the semiconductor device, etc. In this paper, a new fault tolerant control approach is introduced to deal with this matter. When detecting increased thermal stress of one IGBT module, the switching strategy is altered in order to reduce the load of that particular IGBT module and to redistribute the losses and consequently the heat from the affected group or valve to the other switches. Hence, the temperature of the stressed switch is kept under the critical limit and the thermal overload is reduced. In such way the reliability and the lifetime of the converter is maximized even in case of thermal failure. In the proposed novel modulation concept, the balancing of the neutral point potential of the 3L-NPC Inverter is also ensured without any additional hardware.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characteristics of a Switched Reluctance Motor using Grain-Oriented electric steel sheet Predictive current control based multi-pulse flexible-topology thyristor AC/DC converter and its application in wind energy conversion system Hybrid winding concept for toroids Dynamic performances of ballast for T5 fluorescent lamps Recent related technologies for EV/HEV applications in JAPAN
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1