M. Lamich, J. Balcells, D. González, X. Gago, C. Jaen, J. L. Castillo
{"title":"减少并联混合式电源滤波器中前导电流的控制","authors":"M. Lamich, J. Balcells, D. González, X. Gago, C. Jaen, J. L. Castillo","doi":"10.1109/CPE.2009.5156016","DOIUrl":null,"url":null,"abstract":"The main drawback of Shunt Hybrid Filters is the need of leading current injection. This paper describes a strategy to reduce the leading current in a three phase four wires LC coupled parallel hybrid filter for harmonics cancellation. Simulation and experimental results are given to show the behavior of the system.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Control to reduce leading current in a Shunt Hybrid power filter\",\"authors\":\"M. Lamich, J. Balcells, D. González, X. Gago, C. Jaen, J. L. Castillo\",\"doi\":\"10.1109/CPE.2009.5156016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main drawback of Shunt Hybrid Filters is the need of leading current injection. This paper describes a strategy to reduce the leading current in a three phase four wires LC coupled parallel hybrid filter for harmonics cancellation. Simulation and experimental results are given to show the behavior of the system.\",\"PeriodicalId\":272748,\"journal\":{\"name\":\"2009 Compatibility and Power Electronics\",\"volume\":\"102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Compatibility and Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2009.5156016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control to reduce leading current in a Shunt Hybrid power filter
The main drawback of Shunt Hybrid Filters is the need of leading current injection. This paper describes a strategy to reduce the leading current in a three phase four wires LC coupled parallel hybrid filter for harmonics cancellation. Simulation and experimental results are given to show the behavior of the system.