门控心脏动态SPECT图像灌注缺陷的可检测性

Xiaofeng Niu, Yongyi Yang, M. Wernick
{"title":"门控心脏动态SPECT图像灌注缺陷的可检测性","authors":"Xiaofeng Niu, Yongyi Yang, M. Wernick","doi":"10.1109/ISBI.2009.5193204","DOIUrl":null,"url":null,"abstract":"Recently we developed an image reconstruction procedure aimed to unify gated imaging and dynamic imaging in nuclear cardiac imaging. It can yield a single image sequence to show simultaneously both cardiac motion and tracer distribution change over the course of imaging. In this work, we further develop and investigate the feasibility of our gated dynamic imaging procedure for perfusion defect detection in cardiac SPECT imaging, where the challenge is even greater without using fast camera rotations. We study the saliency of temporal kinetic information derived from the reconstructed dynamic images for differentiating defects from normal cardiac perfusion. We also propose several metrics to characterize the salient kinetic information in gated dynamic images. The proposed development was demonstrated using simulated gated cardiac imaging with the NCAT phantom and Tc99m-Teboroxime as the imaging agent.","PeriodicalId":272938,"journal":{"name":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"240 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Detectability of perfusion defect in gated dynamic cardiac SPECT images\",\"authors\":\"Xiaofeng Niu, Yongyi Yang, M. Wernick\",\"doi\":\"10.1109/ISBI.2009.5193204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently we developed an image reconstruction procedure aimed to unify gated imaging and dynamic imaging in nuclear cardiac imaging. It can yield a single image sequence to show simultaneously both cardiac motion and tracer distribution change over the course of imaging. In this work, we further develop and investigate the feasibility of our gated dynamic imaging procedure for perfusion defect detection in cardiac SPECT imaging, where the challenge is even greater without using fast camera rotations. We study the saliency of temporal kinetic information derived from the reconstructed dynamic images for differentiating defects from normal cardiac perfusion. We also propose several metrics to characterize the salient kinetic information in gated dynamic images. The proposed development was demonstrated using simulated gated cardiac imaging with the NCAT phantom and Tc99m-Teboroxime as the imaging agent.\",\"PeriodicalId\":272938,\"journal\":{\"name\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"volume\":\"240 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2009.5193204\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2009.5193204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

最近,我们开发了一种图像重建程序,旨在统一门控成像和动态成像的核心脏成像。它可以产生一个单一的图像序列,同时显示心脏运动和示踪剂分布在成像过程中的变化。在这项工作中,我们进一步开发和研究了我们的门控动态成像程序在心脏SPECT成像中用于灌注缺陷检测的可行性,其中不使用快速相机旋转的挑战甚至更大。我们研究了从重建的动态图像中获得的时间动力学信息的显著性,用于区分心脏灌注缺陷。我们还提出了几个指标来表征门控动态图像中的显著动力学信息。采用NCAT假体和tc99m - teboroxme作为显像剂的模拟门控心脏成像证明了所提出的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detectability of perfusion defect in gated dynamic cardiac SPECT images
Recently we developed an image reconstruction procedure aimed to unify gated imaging and dynamic imaging in nuclear cardiac imaging. It can yield a single image sequence to show simultaneously both cardiac motion and tracer distribution change over the course of imaging. In this work, we further develop and investigate the feasibility of our gated dynamic imaging procedure for perfusion defect detection in cardiac SPECT imaging, where the challenge is even greater without using fast camera rotations. We study the saliency of temporal kinetic information derived from the reconstructed dynamic images for differentiating defects from normal cardiac perfusion. We also propose several metrics to characterize the salient kinetic information in gated dynamic images. The proposed development was demonstrated using simulated gated cardiac imaging with the NCAT phantom and Tc99m-Teboroxime as the imaging agent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automatic alignment of stacks of filament data Analysis of nerve activity and optical signals from mouse brain stem to identify cells generating respiratory rhythms Segmentation and classification of triple negative breast cancers using DCE-MRI Improved registration for large electron microscopy images Special purpose 3-D reconstruction and restoration algorithms for electron microscopy of nanoscale objects and an enabling software toolkit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1