G. Piolain, A. Freudenreich, P. Monthel, M. Brudieu, F. Geffard, P. Garrec
{"title":"远程机器人系统MT200-TAO在阿海珐热室的测试结果","authors":"G. Piolain, A. Freudenreich, P. Monthel, M. Brudieu, F. Geffard, P. Garrec","doi":"10.1109/CARPI.2012.6473378","DOIUrl":null,"url":null,"abstract":"In this article, we present for the first time the lessons learned during an extensive testing campaign of the new telerobotic system MT200-TAO carried out in an active hot-cell. The extremely positive results obtained during the 10 months continuous working period have permitted the validation of the system for its use. The system will be installed first at La Hague plant. A real gain in productivity and higher security are expected.","PeriodicalId":393732,"journal":{"name":"2012 2nd International Conference on Applied Robotics for the Power Industry (CARPI)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Results of a testing campaign of the telerobotic system MT200-TAO in AREVA La Hague's hot-cells\",\"authors\":\"G. Piolain, A. Freudenreich, P. Monthel, M. Brudieu, F. Geffard, P. Garrec\",\"doi\":\"10.1109/CARPI.2012.6473378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, we present for the first time the lessons learned during an extensive testing campaign of the new telerobotic system MT200-TAO carried out in an active hot-cell. The extremely positive results obtained during the 10 months continuous working period have permitted the validation of the system for its use. The system will be installed first at La Hague plant. A real gain in productivity and higher security are expected.\",\"PeriodicalId\":393732,\"journal\":{\"name\":\"2012 2nd International Conference on Applied Robotics for the Power Industry (CARPI)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 2nd International Conference on Applied Robotics for the Power Industry (CARPI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CARPI.2012.6473378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 2nd International Conference on Applied Robotics for the Power Industry (CARPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CARPI.2012.6473378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Results of a testing campaign of the telerobotic system MT200-TAO in AREVA La Hague's hot-cells
In this article, we present for the first time the lessons learned during an extensive testing campaign of the new telerobotic system MT200-TAO carried out in an active hot-cell. The extremely positive results obtained during the 10 months continuous working period have permitted the validation of the system for its use. The system will be installed first at La Hague plant. A real gain in productivity and higher security are expected.