一种改进的LOCA瞬态棒包层变形后阻塞区的模拟模型

Zhiwei Cao, Zhikang Lin, Miaomiao Xu, Jimin He, Jianyang Song
{"title":"一种改进的LOCA瞬态棒包层变形后阻塞区的模拟模型","authors":"Zhiwei Cao, Zhikang Lin, Miaomiao Xu, Jimin He, Jianyang Song","doi":"10.1115/icone29-92787","DOIUrl":null,"url":null,"abstract":"\n During a loss-of-coolant-accident (LOCA) transient, the ballooning and burst of the cladding can lead to blockage of flow path and worsen core coolability. Studies have shown that the core coolability is not changed much up to about 60% blockage ratio, while can be threatened by a severe blockage with a high blockage ratio and long blockage length. A blockage simulation model based on the non-coplanar assumption is widely used in LOCA transient analysis. However, regarding the coplanar deformation observed in experiments, validity of this assumption is questionable. Furthermore, it is found that this model cannot predict reasonable results for severe blockage conditions.\n In this paper, the blockage model is modified for the thermal hydraulic simulation of LOCA transients with the occurrence of severe blockages. Pre-test simulations of a test facility studying the influence of blockage on core coolability have been conducted with the modified model. The results show that, the modified model shows better agreement with the observations in the experiments.","PeriodicalId":325659,"journal":{"name":"Volume 7B: Thermal-Hydraulics and Safety Analysis","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Modified Simulation Model of Blocked Regions After Rod Cladding Deformation During LOCA Transient\",\"authors\":\"Zhiwei Cao, Zhikang Lin, Miaomiao Xu, Jimin He, Jianyang Song\",\"doi\":\"10.1115/icone29-92787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n During a loss-of-coolant-accident (LOCA) transient, the ballooning and burst of the cladding can lead to blockage of flow path and worsen core coolability. Studies have shown that the core coolability is not changed much up to about 60% blockage ratio, while can be threatened by a severe blockage with a high blockage ratio and long blockage length. A blockage simulation model based on the non-coplanar assumption is widely used in LOCA transient analysis. However, regarding the coplanar deformation observed in experiments, validity of this assumption is questionable. Furthermore, it is found that this model cannot predict reasonable results for severe blockage conditions.\\n In this paper, the blockage model is modified for the thermal hydraulic simulation of LOCA transients with the occurrence of severe blockages. Pre-test simulations of a test facility studying the influence of blockage on core coolability have been conducted with the modified model. The results show that, the modified model shows better agreement with the observations in the experiments.\",\"PeriodicalId\":325659,\"journal\":{\"name\":\"Volume 7B: Thermal-Hydraulics and Safety Analysis\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 7B: Thermal-Hydraulics and Safety Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/icone29-92787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 7B: Thermal-Hydraulics and Safety Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/icone29-92787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在失冷事故(LOCA)瞬态过程中,包层的膨胀和破裂会导致流动通道的堵塞和堆芯冷却性的恶化。研究表明,岩心冷却性在堵塞比达到60%左右时变化不大,但堵塞比高、堵塞长度长的严重堵塞会对岩心冷却性造成威胁。基于非共面假设的阻塞模拟模型在LOCA瞬态分析中得到了广泛的应用。然而,对于实验中观察到的共面变形,这一假设的有效性值得怀疑。此外,还发现该模型不能对严重堵塞条件下的合理结果进行预测。本文对堵塞模型进行了修正,对发生严重堵塞时的LOCA瞬态进行了热水力模拟。利用修正后的模型对某试验装置进行了试验前模拟,研究了堵塞对堆芯冷却性的影响。结果表明,修正后的模型与实验结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Modified Simulation Model of Blocked Regions After Rod Cladding Deformation During LOCA Transient
During a loss-of-coolant-accident (LOCA) transient, the ballooning and burst of the cladding can lead to blockage of flow path and worsen core coolability. Studies have shown that the core coolability is not changed much up to about 60% blockage ratio, while can be threatened by a severe blockage with a high blockage ratio and long blockage length. A blockage simulation model based on the non-coplanar assumption is widely used in LOCA transient analysis. However, regarding the coplanar deformation observed in experiments, validity of this assumption is questionable. Furthermore, it is found that this model cannot predict reasonable results for severe blockage conditions. In this paper, the blockage model is modified for the thermal hydraulic simulation of LOCA transients with the occurrence of severe blockages. Pre-test simulations of a test facility studying the influence of blockage on core coolability have been conducted with the modified model. The results show that, the modified model shows better agreement with the observations in the experiments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and Numerical Study on Convective Heat Transfer Characteristic in the Turbulent Region of Molten Salt in Shell-Side of Shell and Tube Heat Exchanger Thermal-Hydraulic Safety Analysis of Natural Circulation Lead-Cooled Fast Reactor SNCLFR-100 Core Based on Porous Medium Approach Verification Dynamic Response for Sinusoidal Wave Flow in Narrow Rectangular Channel Machine Learning Modelling of Decay Heat Removal in High Temperature Gas-Cooled Reactor Three-Dimensional Numerical Simulation of the Natural Circulation Characteristics Based on PLANDTL-DHX for Different Modeling Methods of the Core
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1