R. Talman, B. Roberts, J. Grames, A. Hofler, R. Kazimi, M. Poelker, R. Suleiman
{"title":"共振(纵向和横向)电子偏振法","authors":"R. Talman, B. Roberts, J. Grames, A. Hofler, R. Kazimi, M. Poelker, R. Suleiman","doi":"10.22323/1.324.0028","DOIUrl":null,"url":null,"abstract":"Experiments are proposed to measure (first longitudinal, then, later, using Stern-Gerlach (SG) deflection, transverse) polarization of an electron beam by measuring the excitation induced in a resonant cavity. With ideal resonator construction and positioning there would be no resonator excitation caused directly by the beam charge. But, because the electron charge is so large relative to its magnetic moment, special beam preparation and polarization modulation are required to suppress this background. Signal levels and foreground to background ratios are calculated.","PeriodicalId":166894,"journal":{"name":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Resonant (Longitudinal and Transverse) Electron Polarimetry\",\"authors\":\"R. Talman, B. Roberts, J. Grames, A. Hofler, R. Kazimi, M. Poelker, R. Suleiman\",\"doi\":\"10.22323/1.324.0028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experiments are proposed to measure (first longitudinal, then, later, using Stern-Gerlach (SG) deflection, transverse) polarization of an electron beam by measuring the excitation induced in a resonant cavity. With ideal resonator construction and positioning there would be no resonator excitation caused directly by the beam charge. But, because the electron charge is so large relative to its magnetic moment, special beam preparation and polarization modulation are required to suppress this background. Signal levels and foreground to background ratios are calculated.\",\"PeriodicalId\":166894,\"journal\":{\"name\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22323/1.324.0028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.324.0028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Resonant (Longitudinal and Transverse) Electron Polarimetry
Experiments are proposed to measure (first longitudinal, then, later, using Stern-Gerlach (SG) deflection, transverse) polarization of an electron beam by measuring the excitation induced in a resonant cavity. With ideal resonator construction and positioning there would be no resonator excitation caused directly by the beam charge. But, because the electron charge is so large relative to its magnetic moment, special beam preparation and polarization modulation are required to suppress this background. Signal levels and foreground to background ratios are calculated.