{"title":"亚波长近场成像使用交叉极化槽与电线插入","authors":"T. Pochiraju, O. Malyuskin, V. Fusco","doi":"10.1109/URSI-EMTS.2010.5637171","DOIUrl":null,"url":null,"abstract":"In this paper we study sub-wavelength imaging by a new type of probe comprising a single cross polarized slot cut into a metal plate which has a wire inserted along its length. Using this arrangement we show by numerical simulation and experimentally that the transmitted near field can be enhanced up to 25dB with respect to the unloaded slot transmission. Moreover, superior near field squeezing results in 0.14 λ FWHM at 0.1λ distance from the slot. The arrangement yields image resolution capability of better than λ/4 at distance between 0.1λ and 0.2λ from the slot.","PeriodicalId":404116,"journal":{"name":"2010 URSI International Symposium on Electromagnetic Theory","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Sub-wavelength near field imaging using a cross polarised slot with wire insert\",\"authors\":\"T. Pochiraju, O. Malyuskin, V. Fusco\",\"doi\":\"10.1109/URSI-EMTS.2010.5637171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we study sub-wavelength imaging by a new type of probe comprising a single cross polarized slot cut into a metal plate which has a wire inserted along its length. Using this arrangement we show by numerical simulation and experimentally that the transmitted near field can be enhanced up to 25dB with respect to the unloaded slot transmission. Moreover, superior near field squeezing results in 0.14 λ FWHM at 0.1λ distance from the slot. The arrangement yields image resolution capability of better than λ/4 at distance between 0.1λ and 0.2λ from the slot.\",\"PeriodicalId\":404116,\"journal\":{\"name\":\"2010 URSI International Symposium on Electromagnetic Theory\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 URSI International Symposium on Electromagnetic Theory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/URSI-EMTS.2010.5637171\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 URSI International Symposium on Electromagnetic Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/URSI-EMTS.2010.5637171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sub-wavelength near field imaging using a cross polarised slot with wire insert
In this paper we study sub-wavelength imaging by a new type of probe comprising a single cross polarized slot cut into a metal plate which has a wire inserted along its length. Using this arrangement we show by numerical simulation and experimentally that the transmitted near field can be enhanced up to 25dB with respect to the unloaded slot transmission. Moreover, superior near field squeezing results in 0.14 λ FWHM at 0.1λ distance from the slot. The arrangement yields image resolution capability of better than λ/4 at distance between 0.1λ and 0.2λ from the slot.