{"title":"爱尔兰输电线路上的雷暴","authors":"R. C. Cuffe","doi":"10.1049/JI-2.1947.0088","DOIUrl":null,"url":null,"abstract":"A brief account is given of an investigation of lightning disturbances on the Electricity Supply Board's system in Ireland. Figures for the average lightning faults per 100 miles of line per annum for the 110-, 38- and 10-kV systems are derived from a 10-year record of such faults. Using the records of the 10-kV system as a basis, the author constructs a map showing the variation of lightning trouble intensity for different localities in Ireland. An account is also given of some magnetic link observations of lightning surges on the earth leads from 110-kV overhead earthwires and from 38-kV lightning arresters. The results obtained appear to show that a large proportion of the discharge currents of such arresters have values below 1 000 amp. Since the usual practice has been to mount magnetic links so that only currents in excess of about 3 000 amp are recorded, it would seem that many arrester operations may have escaped detection, and the results of such observations could therefore lead to erroneous conceptions as to the frequency of operation of medium-voltage arresters. Since modern lightning technique is largely a question of the economics of individual applications, the author stresses the importance of obtaining adequate local lightning data wherever possible.","PeriodicalId":307627,"journal":{"name":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1947-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Lightning surges on transmission lines in Ireland\",\"authors\":\"R. C. Cuffe\",\"doi\":\"10.1049/JI-2.1947.0088\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A brief account is given of an investigation of lightning disturbances on the Electricity Supply Board's system in Ireland. Figures for the average lightning faults per 100 miles of line per annum for the 110-, 38- and 10-kV systems are derived from a 10-year record of such faults. Using the records of the 10-kV system as a basis, the author constructs a map showing the variation of lightning trouble intensity for different localities in Ireland. An account is also given of some magnetic link observations of lightning surges on the earth leads from 110-kV overhead earthwires and from 38-kV lightning arresters. The results obtained appear to show that a large proportion of the discharge currents of such arresters have values below 1 000 amp. Since the usual practice has been to mount magnetic links so that only currents in excess of about 3 000 amp are recorded, it would seem that many arrester operations may have escaped detection, and the results of such observations could therefore lead to erroneous conceptions as to the frequency of operation of medium-voltage arresters. Since modern lightning technique is largely a question of the economics of individual applications, the author stresses the importance of obtaining adequate local lightning data wherever possible.\",\"PeriodicalId\":307627,\"journal\":{\"name\":\"Journal of the Institution of Electrical Engineers - Part II: Power Engineering\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1947-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Institution of Electrical Engineers - Part II: Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/JI-2.1947.0088\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Institution of Electrical Engineers - Part II: Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/JI-2.1947.0088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

简要叙述了对爱尔兰电力供应委员会系统雷电干扰的调查。110千伏、38千伏和10千伏系统每年每100英里线路的平均雷击故障数据来自10年的此类故障记录。以10kv系统的记录为基础,作者绘制了爱尔兰不同地区雷电灾害强度变化图。还叙述了从110千伏架空接地线和38千伏避雷器对地引线上的雷击浪涌的一些磁链观测。所获得的结果似乎表明,这类避雷器的放电电流的很大一部分值低于1000安培。由于通常的做法是安装磁链接,以便仅记录超过约3000安培的电流,因此似乎许多避雷器的操作可能逃过了检测,并且这种观察的结果因此可能导致对中压避雷器操作频率的错误概念。由于现代闪电技术在很大程度上是个别应用的经济问题,作者强调尽可能获得充足的当地闪电数据的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lightning surges on transmission lines in Ireland
A brief account is given of an investigation of lightning disturbances on the Electricity Supply Board's system in Ireland. Figures for the average lightning faults per 100 miles of line per annum for the 110-, 38- and 10-kV systems are derived from a 10-year record of such faults. Using the records of the 10-kV system as a basis, the author constructs a map showing the variation of lightning trouble intensity for different localities in Ireland. An account is also given of some magnetic link observations of lightning surges on the earth leads from 110-kV overhead earthwires and from 38-kV lightning arresters. The results obtained appear to show that a large proportion of the discharge currents of such arresters have values below 1 000 amp. Since the usual practice has been to mount magnetic links so that only currents in excess of about 3 000 amp are recorded, it would seem that many arrester operations may have escaped detection, and the results of such observations could therefore lead to erroneous conceptions as to the frequency of operation of medium-voltage arresters. Since modern lightning technique is largely a question of the economics of individual applications, the author stresses the importance of obtaining adequate local lightning data wherever possible.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The flash tube and its applications Corrigendum: The predetermination of the magnetic properties of ferromagnetic laminae at power and audio frequencies The authors' replies to the discussion on "Development of locators of small metallic bodies buried in the ground" Development of locators of small metallic bodies buried in the ground Transformer economic efficiency
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1