交流电机驱动输入电磁干扰滤波器的重新设计,电机电压主动补偿

M. C. Di Piazza, A. Ragusa, G. Vitale
{"title":"交流电机驱动输入电磁干扰滤波器的重新设计,电机电压主动补偿","authors":"M. C. Di Piazza, A. Ragusa, G. Vitale","doi":"10.1109/CPE.2009.5156052","DOIUrl":null,"url":null,"abstract":"This paper deals with the design of the input EMI filter in an AC motor drive when the compensation of common mode emissions towards the motor is performed by an active filter. Both the drive and the active filter have been analyzed through an high frequency circuit model in order to identify the main propagation loops for CM disturbance. In particular the EMI emissions towards the grid are evaluated also in comparison with those generated in a configuration without the active filter. The accuracy of the model has been assessed by experimental measurements. Results show a reduction of CM EMI towards the grid in the lower frequency range of conducted emissions when the active filter is installed. This demonstrates that EMC requirements compliance of the drive can be achieved with a reduction in the size of the input EMI filter.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Input EMI filter re-design in AC motor drives with active compensation of motor CM voltage\",\"authors\":\"M. C. Di Piazza, A. Ragusa, G. Vitale\",\"doi\":\"10.1109/CPE.2009.5156052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the design of the input EMI filter in an AC motor drive when the compensation of common mode emissions towards the motor is performed by an active filter. Both the drive and the active filter have been analyzed through an high frequency circuit model in order to identify the main propagation loops for CM disturbance. In particular the EMI emissions towards the grid are evaluated also in comparison with those generated in a configuration without the active filter. The accuracy of the model has been assessed by experimental measurements. Results show a reduction of CM EMI towards the grid in the lower frequency range of conducted emissions when the active filter is installed. This demonstrates that EMC requirements compliance of the drive can be achieved with a reduction in the size of the input EMI filter.\",\"PeriodicalId\":272748,\"journal\":{\"name\":\"2009 Compatibility and Power Electronics\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Compatibility and Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2009.5156052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文讨论了用有源滤波器对交流电机共模辐射进行补偿时输入EMI滤波器的设计。通过高频电路模型对驱动和有源滤波器进行了分析,以确定CM扰动的主要传播回路。特别是,对电网的电磁干扰发射也进行了评估,并与没有有源滤波器的配置中产生的电磁干扰发射进行了比较。该模型的准确性已通过实验测量进行了评估。结果表明,当安装有源滤波器时,在传导发射的较低频率范围内,CM对电网的电磁干扰减少。这表明,驱动器的EMC要求符合可以通过减少输入EMI滤波器的尺寸来实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Input EMI filter re-design in AC motor drives with active compensation of motor CM voltage
This paper deals with the design of the input EMI filter in an AC motor drive when the compensation of common mode emissions towards the motor is performed by an active filter. Both the drive and the active filter have been analyzed through an high frequency circuit model in order to identify the main propagation loops for CM disturbance. In particular the EMI emissions towards the grid are evaluated also in comparison with those generated in a configuration without the active filter. The accuracy of the model has been assessed by experimental measurements. Results show a reduction of CM EMI towards the grid in the lower frequency range of conducted emissions when the active filter is installed. This demonstrates that EMC requirements compliance of the drive can be achieved with a reduction in the size of the input EMI filter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ancillary services to grids provided with distributed generation Trigeneration energy system for the campus of the University of Rijeka High frequency grid impedance analysis with three-phase converter and FPGA based tolerance band controller Performances of the adjustable speed decoupled generation systems Power quality immunity in factory automation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1