{"title":"快速输电系统保护系统的成本效益分析:发表于第71届保护继电器工程师年会上","authors":"Brian Ehsani, J. Hulme","doi":"10.1109/CPRE.2018.8349787","DOIUrl":null,"url":null,"abstract":"This paper analyzes the effects of reducing tripping times on the cost of a transmission system. A range of trip times are examined to demonstrate the difference in the initial price tag of a transmission system as well as the ongoing cost. The increased cost of a slower tripping scheme is analyzed by investigating the relationship between substation ground grid and transmission line neutral conductor sizing and cost.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Cost benefit analysis of faster transmission system protection systems: Presented at the 71st annual conference for protective relay engineers\",\"authors\":\"Brian Ehsani, J. Hulme\",\"doi\":\"10.1109/CPRE.2018.8349787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the effects of reducing tripping times on the cost of a transmission system. A range of trip times are examined to demonstrate the difference in the initial price tag of a transmission system as well as the ongoing cost. The increased cost of a slower tripping scheme is analyzed by investigating the relationship between substation ground grid and transmission line neutral conductor sizing and cost.\",\"PeriodicalId\":285875,\"journal\":{\"name\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2018.8349787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cost benefit analysis of faster transmission system protection systems: Presented at the 71st annual conference for protective relay engineers
This paper analyzes the effects of reducing tripping times on the cost of a transmission system. A range of trip times are examined to demonstrate the difference in the initial price tag of a transmission system as well as the ongoing cost. The increased cost of a slower tripping scheme is analyzed by investigating the relationship between substation ground grid and transmission line neutral conductor sizing and cost.