{"title":"变压器油试验用交叉电容式传感器的标定","authors":"Mahammad Aamir Mahmood, Obaidur Rahman, S. A. Khan","doi":"10.1109/ASIANCON55314.2022.9908609","DOIUrl":null,"url":null,"abstract":"In this work, an effort is being made to calibrate a cross capacitive sensor when used to measure the concentration of insulation degradation parameters in transformer oil. The cross capacitive sensor offers many privileges in oil-based sensing. Moisture and 2-furfuraldehyde (2-FAL) are the two most important insulation degradation by- products. The concentration of moisture and 2-FAL with in the oil has been directly related to the condition of transformer insulation. The cross-capacitive sensor is calibrated using regression analysis for the measurement of 2-FAL, moisture and mixture of 2-FAL and moisture in the oil.","PeriodicalId":429704,"journal":{"name":"2022 2nd Asian Conference on Innovation in Technology (ASIANCON)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Calibration of Cross Capacitive Sensor used for Transformer Oil Testing\",\"authors\":\"Mahammad Aamir Mahmood, Obaidur Rahman, S. A. Khan\",\"doi\":\"10.1109/ASIANCON55314.2022.9908609\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, an effort is being made to calibrate a cross capacitive sensor when used to measure the concentration of insulation degradation parameters in transformer oil. The cross capacitive sensor offers many privileges in oil-based sensing. Moisture and 2-furfuraldehyde (2-FAL) are the two most important insulation degradation by- products. The concentration of moisture and 2-FAL with in the oil has been directly related to the condition of transformer insulation. The cross-capacitive sensor is calibrated using regression analysis for the measurement of 2-FAL, moisture and mixture of 2-FAL and moisture in the oil.\",\"PeriodicalId\":429704,\"journal\":{\"name\":\"2022 2nd Asian Conference on Innovation in Technology (ASIANCON)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 2nd Asian Conference on Innovation in Technology (ASIANCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASIANCON55314.2022.9908609\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd Asian Conference on Innovation in Technology (ASIANCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASIANCON55314.2022.9908609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibration of Cross Capacitive Sensor used for Transformer Oil Testing
In this work, an effort is being made to calibrate a cross capacitive sensor when used to measure the concentration of insulation degradation parameters in transformer oil. The cross capacitive sensor offers many privileges in oil-based sensing. Moisture and 2-furfuraldehyde (2-FAL) are the two most important insulation degradation by- products. The concentration of moisture and 2-FAL with in the oil has been directly related to the condition of transformer insulation. The cross-capacitive sensor is calibrated using regression analysis for the measurement of 2-FAL, moisture and mixture of 2-FAL and moisture in the oil.